Instruction manual
1 - 3
1. FUNCTIONS AND CONFIGURATION
1.2 Servo amplifier standard specifications
Servo Amplifier
MR-J3-
-RJ004
Item
40B 70B 200B 350B 500B
Voltage/frequency
3-phase 200 to 230VAC, 50/60Hz or 1-
phase 230VAC, 50/60Hz
3-phase 200 to 230VAC, 50/60Hz
Permissible voltage fluctuation
3-phase 200 to 230VAC: 170 to 253VAC
1-phase 230VAC: 207 to 253VAC
3-phase 170 to 253VAC
Permissible frequency fluctuation Within 5%
Power supply capacity Refer to Section 10.2
Power supply
Inrush current Refer to Section 10.5
Voltage, frequency 1-phase 200 to 230VAC, 50/60Hz
Permissible voltage
fluctuation
1-phase 170 to 253VAC
Permissible frequency
fluctuation
Within
5%
Input 30W 45W
Control circuit
power supply
Inrush current Refer to Section 11.5
Voltage, frequency DC24V 10%
Interface power
supply
Power supply capacity (Note 1) 150mA or more
Control System Sine-wave PWM control, current control system
Dynamic brake Built-in
Protective functions
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal
relay), linear servo motor overheat protection, encoder error protection, regenerative brake
error protection, undervoltage, instantaneous power failure protection, overspeed protection,
excessive error protection
Structure
Self-cooled, open
(IP00)
Force-cooling, open (IP00)
[ ] (Note 2) 0 to 55 (non-freezing) During
operation
[
] 32 to 131 (non-freezing)
[ ] 20 to 65 (non-freezing)
Ambient
temperature
In storage
[
] 4 to 149 (non-freezing)
In operation Ambient
humidity
In storage
90%RH or less (non-condensing)
Ambient
Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude Max. 1000m (3280ft) above sea level
Environment
Vibration 5.9 [m/s
2
] or less
[kg] 1.0 1.4 2.3 2.3 4.6
Mass
[lb] 2.2 3.1 5.071 5.071 10.1
Note 1. 150mA is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of
I/O points.
2. When closely mounting the servo amplifier of 3.5kW or less, operate them at the ambient temperatures of 0 to 45
or at 75%
or smaller effective load ratio.