Instruction manual

6 - 16
6. PARAMETERS
6.6 Special setting parameters (No. PS
)
6.6.1 Parameter list
POINT
For details of the parameters in which columns MR-J3- B is written, refer to
the MR-J3-
B Servo Amplifier Instruction Manual.
Parameter whose symbol is preceded by * is made valid with the following
conditions.
* : Set the parameter value, switch power off once after setting, and then
switch it on again, or perform the controller reset.
**: Set the parameter value, switch power off once, and then switch it on
again.
Never change the parameters for the manufacturer setting.
No. Symbol Name Initial Value Unit
Reference
PS01 **LIT1 Linear function selection 1
0301h
PS02
**LIM Linear encoder resolution setting Numerator 1000
PS03
**LID Linear encoder resolution setting Denominat 1000
PS04
**LIT2 Linear function selection 2 0003h
PS05 LB1 Linear servo motor control position deviation error detection level 50
mm
PS06
LB2 Linear servo motor control speed deviation error detection level 1000
mm/s
PS07 LB3 Linear servo motor control thrust deviation error detection level 100
%
PS08
*LIT3 Linear function selection 3 0010h
PS09 LPWM Magnetic pole detection voltage level 30
%
PS10
LFH
At magnetic pole detection current detection method Identification signal
frequency
5
Hz
PS11
LIDH
At magnetic pole detection current detection method Identification signal
amplitude.
100
%
PS12
500
PS13
0000h
PS14
0000h
PS15
0000h
PS16
0000h
PS17
0000h
PS18
0000h
PS19
0000h
PS20
0000h
PS21
0000h
PS22
0000h
PS23
0000h
PS24
0000h
PS25
0000h
PS26
0000h
PS27
0000h
PS28
0000h
PS29
0000h
PS30
0000h
PS31
0000h
PS32
For manufacturer setting
0000h
Section 6.6.2