Instruction manual

6 - 5
6. PARAMETERS
Classification
No.
Symbol
Name and Function
Initial
Value
Unit
Setting range
PA16 *ENR2
Encoder output pulse 2
This parameter is made valid when parameter No.PC03 is set to "
3
".
Set the encoder pulses (A-phase, B-phase) output by the servo
amplifier.
Set the encoder pulses output by the servo amplifier by parameter
No.PA15 & parameter No.PA16.
Travel [pulse] of the linear encoder is multiplied by the set value.
Output pulse
Travel of linear encoder
Set value of parameter No.PA15
Set value of parameter No.PA16
[pulse]
The number of A/B-phase pulses actually output is 1/4 times greater
than the preset number of pulses. Also, the maximum output
frequency is 4.6Mpps (after multiplication by 4). Use this parameter
within the range.
When the set value is "0 (initial value)", it is internally treated as "1".
0 1 to 65535
Basic setting parameter
PA19 *BLK
Parameter write inhibit
Applicable parameters
Setti
ng
Opera
tion
No.PA
No.PB
No.PC
No.PD
No.PS
Refer
ence
0000h
Write
Refer
ence
000Bh
Write
Refer
ence
000Ch
Write
Refer
ence
000Dh
Write
Refer
ence
100Bh
Write
Paramete
r No.
PA19
only
Refer
ence
100Dh
Write
Paramete
r No.
PA19
only
000Dh Refer to the
name and
function
column