Specifications
32
MITSUBISHI ELECTRIC
OPTIONS AND PERIPHERAL EQUIPMENT
4
왎
Noise Filters
U1
V1
W1
왎 Brake Resistors
Resistor Servo amplifier
Power
capacity
[W]
Resistance
(W)
Weight
[kg]
Dimensions
(WxHxD)
Order
number
MR-RFH75-40
MR-J3-10A/B/T – MR-J3-60A/B/T,
MR-J3-70A/B/T and MR-J3-100A/B/T
150 40 0.16 36 x 27 x 90 137279
MR-RFH220-40 MR-J3-70A/B/T and MR-J3-100A/B/T 400 40 0.42 36 x 27 x 200 137278
MR-RFH400-13
MR-J3-200A/B/T, MR-J3-350A/B/T
and MR-J3-500A/B/T
600 13 0.73 36 x 27 x 320 137277
MR-RFH400-6.7 MR-J3-700A/B/T 600 6.7 0.73 36 x 27 x 320 137275
MR-PWR-R T 400-120
MR-J3-60A4/B4/T4
and MR-J3-100A4/B4/T4
400 120 0.4 36 x 27 x 200 154746
MR-PWR-R T 600-47
MR-J3-200A4/B4/T4
and MR-J3-350A4/B4/T4
600 47 0.64 36 x 27 x 320 154751
MR-PWR-R T 600-26
MR-J3-500A4/B4/T4
and MR-J3-700A4/B4/T4
600 26 0.64 36 x 27 x 320 154752
Filter
햲
Servo amplifier
Power
loss [W]
Rated
current [A]
Leakage
햳
current [mA]
Weight
[kg]
Order
number
MF-2F230-006.230MFa
MR-J3-10A/B/T – MR-J3-60A/B/T 10 6 < 26 0.45 189332
MF-2F230-006.230MFb
MR-J3-70A/B/T 10 6 < 26 0.45 189331
MF-3F480-010.233MF
MR-J3-60A4/B4/T4, MR-J3-100A/B/T
and MR-J3-100A4/B4/T4
9 10 < 7 1.0 208775
MF-3F480-015.230MF3
MR-J3-200A/B/Tand MR-J3-200A4/B4/T4 12 15 < 4
햳
1.5 203463
MF-3F480-015.233MF
MR-J3-350A4/B4/T4 16 15 < 20 2.0 208776
MF-3F480-025.230MF3
햴
MR-J3-350A/B/T, MR-J3-500A4/B4/T4
and MR-J3-700A4/B4/T4
20 25 < 4 3.0 203854
MF-3F480-050.230MF3
MR-J3-500A/B/Tand MR-J3-700A/B/T 40 50 < 4
햳
4.0 203855
햲
All filters can provide conformity with the limits for environment 1, restricted distribution up to 50 m or environment 1, unrestricted
distibution up to 20 m.
햳
At normal operation: voltage difference between 2 phases < 3 % / at fault occurrence (value in brackets) : 2 dead phases (worst case)
햴
No foot print filter
For complying with the E MC directives of
the European Community regarding
the electromagnetic compatibility, the
servo amplifiers have to be equipped
with a noise filter across the input circuit.
Additionally it has to be installed and
wired according to the EMC direc t ives.
The filter units are d esigned to reduce
mains conducted RFI emissions to meet
the European standard EN 61800-3.
More details are enclosed in the
installation sheet of the MR-J3 filters.
If the regenerative power exceeds the
power of the built-in resistor, the following
listed optional brake resistors can be used.
/// NOISE FILTERS AND BRAKE RESISTORS/// NOISE FILTERS AND BRAKE RESISTORS