Instruction manual
3 - 45
3. SIGNALS AND WIRING
3.13 Control axis selection
POINT
The control axis number set to rotary axis setting switch (SW1) should be the
same as the one set to the servo system controller.
Use the rotary axis setting switch (SW1) to set the control axis number for the servo. If the same numbers
are set to different control axes in a single communication system, the system will not operate properly. The
control axes may be set independently of the SSCNET
cable connection sequence.
8
7
6
5
4
3
2
1
0
F
E
D
C
B
A
9
Rotary axis setting switch (SW1)
Down
Up
Test operation select switch (SW2-1)
Set the test operation select switch to the "Up" position, when
performing the test operation mode by using MR Configurator
(Servo configuration).
Spare (Be sure to set to the "Down" position.)
(Note) SW2
Note. This table indicates the status when the switch is set to "Down".
(Default)
Spare Rotary axis setting switch (SW1) Description Display
0Axis No.101
1Axis NO.202
2Axis NO.303
3Axis NO.404
4Axis NO.505
5Axis NO.606
6Axis NO.707
7Axis NO.808
8Axis NO.909
9Axis NO.1010
AAxis NO.1111
BAxis NO.1212
CAxis NO.1313
DAxis NO.1414
EAxis NO.1515
Down
(Be sure to set to the
"Down" position.)
FAxis NO.1616