Instruction manual

3 - 43
3. SIGNALS AND WIRING
3.11.3 Wiring diagrams (HF-MP series HF-KP series servo motor)
POINT
For HF-SP series HC-RP series HC-UP series HC-LP series servo motors,
refer to Section 3.10.2 (2).
(1) When cable length is 10m or less
AWG20
AWG20
MR-BKS1CBL M-A1-L
MR-BKS1CBL M-A2-L
MR-BKS1CBL M-A1-H
MR-BKS1CBL M-A2-H
(Note 2)
B1
B2
24VDC power
supply for
electromagnetic
brake
Servo motor
10m or less
-
+
(Note3)
Electromagnetic
brake (MBR)
Forced stop
(EM1)
(Note 3)
Servo
alarm
Note 1. Shut off the circuit on detection of the servo amplifier alarm.
2. Connect a surge absorber as close to the servo motor as possible.
3. There is no polarity in electromagnetic brake terminals (B1 and B2).
When fabricating the motor brake cable MR-BKS1CBL- M-H, refer to Section 11.1.4.
(2) When cable length exceeds 10m
When the cable length exceeds 10m, fabricate an extension cable as shown below on the customer side. In
this case, the motor power supply cable pulled from the servo motor should be within 2m long.
Refer to Section 11.8 for the wire used for the extension cable.
AWG20
AWG20
MR-BKS1CBL2M-A1-L
MR-BKS1CBL2M-A2-L
MR-BKS1CBL2M-A1-H
MR-BKS1CBL2M-A2-H
MR-BKS2CBL03M-A1-L
MR-BKS2CBL03M-A2-L
B1
B2
24VDC power
supply for
electromagnetic
brake
50m or less
Extension cable (To be fabricated)
(Note 2)
2m or less
-
+
Servo motor
(Note 3)
Relay connector for
extension cable
(Note 3)
Relay connector for motor
power supply cable
(Note 4)
Eloectromagnetic
brake (MBR)
Forced stop
(EM1)
(Note 3)
Servo
alarm
Note 1. Shut off the circuit on detection of the servo amplifier alarm.
2. Connect a surge absorber as close to the servo motor as possible.
3. Use of the following connectors is recommended when ingress protection (IP65) is necessary.
4. There is no polarity in electromagnetic brake terminals (B1 and B2).
Relay Connector Description
Protective
Structure
Relay connector for
extension cable
CM10-CR2P-
(DDK)
Wire size: S, M, L
IP65
Relay connector for
motor power supply
cable
CM10-SP2S-
(DDK)
Wire size: S, M, L
IP65