Instruction manual

11 - 54
11. OPTIONS AND AUXILIARY EQUIPMENT
Table 11.1 Recommended wires
Wires [mm
2
]
Servo amplifier
1)
L
1
L
2
L
3
2) L
11
L
21
3)
U
V W
4) P C5) B1B2
6)
BU
BV BW
7)
OHS1 OHS2
MR-J3-10B (1)
MR-J3-20B (1)
MR-J3-40B (1)
MR-J3-60B
MR-J3-70B
1.25 (AWG16)
MR-J3-100B
2 (AWG14)
2 (AWG14)
MR-J3-200B 3.5 (AWG12) 3.5 (AWG12)
MR-J3-350B 5.5 (AWG10) 5.5 (AWG10)
MR-J3-500B
(Note2)
5.5(AWG10):
a(note1)
5.5(AWG10):
a(note1)
2(AWG14)
MR-J3-700B
(Note2)
8(AWG8):
b(note1)
8(AWG8):
b(note1)
3.5(AWG12): a
MR-J3-11KB
(Note2)
14(AWG6): c 22(AWG4): d
MR-J3-15KB
(Note2)
22(AWG4): d 30(AWG2): e
MR-J3-22KB
(Note2)
50(AWG1/0): f 60(AWG2/0): f
5.5(AWG10): a
MR-J3-11KB4 8(AWG8): b 8(AWG8): b 3.5(AWG12): a
MR-J3-15KB4
MR-J3-22KB4
14(AWG6): c
1.25 (AWG16)
22(AWG4): d 5.5(AWG10): a
1.25 (AWG16)
2(AWG14) 1.25(AWG16)
Note 1. For crimping terminals and applicable tools, refer to Table 11.2.
2. When connecting to the terminal block, be sure to use the screws which are provided with the terminal block.
Use wires 6) of the following sizes with the brake unit (FR-BU) and power regeneration converter (FR-RC).
Model Wires[mm
2
]
FR-BU-15K 3.5(AWG12)
FR-BU-30K 5.5(AWG10)
FR-BU-55K 14(AWG6)
FR-BU-H15K
FR-BU-H30K
3.5(AWG12)
FR-BU-H55K 8(AWG8)
FR-RC-15K 14(AWG6)
FR-RC-30K 14(AWG6)
FR-RC-55K 22(AWG4)
FR-RC-H15K 14(AWG6)
FR-RC-H30K 14(AWG6)
FR-RC-H55K 14(AWG6)