Instruction manual
11 - 46
11. OPTIONS AND AUXILIARY EQUIPMENT
(b) DBU-11K-4 DBU-22K-4
15
51
25
15
73.75 7
25150
10
200
170
178.5
179.5
15
260
280
43
10
2- 7Mounting hole
195
228
26
26
210
2.3
Mass: 6.7[kg]
a
TE1
Tightening torque: 0.8[N m](7[lb in])
Screw: M3.5
b 13 14
Terminal block
WVU
Tightening torque: 1.2[N m](10.6[lb in])
Screw: M4
TE2
Wire [mm
2
]
Dynamic brake
a
bUV W
DBU-11K 2 5.5
DBU-15K, 22K 2 5.5
POINT
Configure up a sequence which switches off the contact of the brake unit after
(or as soon as) it has turned off the servo on signal at a power failure or
failure.
For the braking time taken when the dynamic brake is operated, refer to
Section 10.3.
The brake unit is rated for a short duration. Do not use it for high duty.
When the dynamic brake is used, the power supply voltage is restricted as
indicated below.
3-Phase 170 to 220VAC/50Hz
3-Phase 170 to 242VAC/60Hz