Instruction manual

11 - 35
11. OPTIONS AND AUXILIARY EQUIPMENT
(3) Outside dimensions of the power regeneration converters
[Unit : mm]
AA
A
C
F
K
E
E
B
A
B
E
D
2- D hole
Rating plate
Front cover
Display
panel
window
Mounting foot (removable)
Mounting foot
movable
Cooling fan
Heat generation area outside mounting dimensio
n
Power
regeneration
converter
AAABBAC D EEEK F
Approx.
Mass [kg(Ib)]
FR-RC-15K 270 200 450 432 195 10 10 8 3.2 87
19
(41.888)
FR-RC-30K
FR-RC-H30K
340 270 600 582 195 10 10 8 3.2 90
31
(68.343)
FR-RC-55K
FR-RC-H55K
480 410 700 670 250 12 15 15 3.2 135
55
(121.3)
(4) Mounting hole machining dimensions
When the power regeneration converter is fitted to a totally enclosed type box, mount the heat generating
area of the converter outside the box to provide heat generation measures. At this time, the mounting
hole having the following dimensions is machined in the box.
[Unit : mm]
Model a b D AA BA
FR-RC-15K 260 412 10 200 432
FR-RC-30K
FR-RC-H30K
330 562 10 270 582
FR-RC-55K
FR-RC-H55K
470 642 12 410 670
(AA)
(BA)
b
a
(2- D hole)
(Mounting hole)