Instruction manual

5 - 18
5. PARAMETERS
5.3.2 List of details
No. Symbol Name and Function
Initial
Value
Unit
Setting
Range
PC01 *ERZ Error excessive alarm level
This parameter cannot be used in the speed control mode.
Set error excessive alarm level with rotation amount of servo motor.
3 rev 1
to
200
PC02 MBR Electromagnetic brake sequence output
Used to set the delay time (Tb) between electronic brake interlock (MBR) and the base
drive circuit is shut-off.
0 ms 0
to
1000
PC03 *ENRS Encoder output pulse selection
Use to select the, encoder output pulse direction and encoder pulse output setting.
CW
Encoder pulse output phase changing
Changes the phases of A, B-phase encoder pulses output .
A phase
B phase
CCW
Servo motor rotation direction
Set value
0
1
Encoder output pulse setting selection (refer to parameter No. PA15)
0: Output pulse designation
1: Division ratio setting
00
A phase
B phase
A phase
B phase
A phase
B phase
0000h Refer to
Name
and
function
column.
PC04 **COP1 Function selection C-1
Select the encoder cable communication system selection.
00
Encoder cable communication system selection
0: Two-wire type
1: Four-wire type
The following encoder cables are of 4-wire type.
MR-EKCBL30M-L
MR-EKCBL30M-H
MR-EKCBL40M-H
MR-EKCBL50M-H
The other encoder cables are all of 2-wire type.
Incorrect setting will result in an encoder alarm 1 (16) or encoder
alarm 2 (20).
0
0000h Refer to
Name
and
function
column.
PC05 **COP2 Function selection C-2
Motor-less operation select.
Motor-less operation select.
0: Valid
1: Invalid
000
0000h Refer to
Name
and
function
column.
PC06 For manufacturer setting
Do not change this value by any means.
0000h
PC07 ZSP Zero speed
Used to set the output range of the zero speed (ZSP).
Zero speed signal detection has hysteresis width of 20r/min (Refer to Section 3.5 (2) (b))
50 r/min 0
to
10000
PC08 For manufacturer setting
Do not change this value by any means.
0