Specifications
Options
84
● Radio noise filter (FR-BIF, FR-BIF-H)
Effectively controls noise transmitted from the power-supply side of the servo amplifier or converter unit, and is especially effective
for radio frequency bands under 10MHz. Only for input.
FR-BIF
FR-BIF-H
MR-J2S-22KMor smaller, MR-J2S-30KM or 37KM
MR-J2S-11KM4 to MR-J2S-55KM4
External dimensions
MC
FR-BIF
or
FR-BIF-H
L1
Servo-amp
L2
L3
NFB
MC
L1
L2
L3
Converter unit
NFB
FR-BIF
or
FR-BIF-H
Power-
supply
Power-
supply
Connections
MR-J2S-22KM(4) or smaller
MR-J2S-30KM(4) or larger
1. Cannot be connected to output side of the servo-amplifier or converter unit.
2. Wiring should be as short as possible, and please connect to the terminal
block of the unit.
Notes:
Unit: mm (inch)
Unit: mm (inch) Unit: mm (inch)
Mounting Panel cutting dimensions
175 (6.89)
300 (11.81)
125 (4.92)
440 (17.32)30 (1.18) 160 (6.3)
Servo-amp or converter unit
Panel
Panel
Attachment
MR-ACN(P)MKMR-JACN15K MR-JACN22K
444 (17.48)
575 (22.64)15 (0.59)
605 (23.82)
DC
DD
DB
DA
4-M10 screw
MR-ACN(P)MKMR-JACNMK
DB
535 (21.06)
39.5 (1.56)
39.5 (1.56)
331 (13.03)
DC
DD
510 (20.08)
18 (0.71)
DA
4-M10 screw
Drill hole
Drill hole
260 (10.24)
11.5 (0.45)
3.2
(0.126)
155 (6.1)
105
(4.13)
145
(5.71)
20 (0.79)
35
(1.38)
400 (15.75)
Servo-amp
Panel
Panel
145 (5.71)
68 (2.68)
Panel
MR-JACN15K
MR-JACN22K
MR-ACNP55K
MR-ACN30K
MR-ACN55K
DA DB DC DD
Model
Applicable servo-amp
converter unit
MR-J2S-11KA/B
MR-J2S-15KA/B
MR-J2S-11KA4/B4
MR-J2S-15KA4/B4
MR-J2S-22KA/B
MR-J2S-22KA4/B4
MR-HP30KA,HP55KA4
MR-J2S-30KA4/B4
MR-J2S-30KA/B
MR-J2S-37KA/B
MR-J2S-37KA4/B4
MR-J2S-45KA4/B4
MR-J2S-55KA4/B4
Variable dimensions
455
(17.91)
406
(15.98)
360
(14.17)
440
(17.32)
385
(15.16)
336
(13.23)
290
(11.42)
370
(14.57)
205
(8.07)
156
(6.14)
110
(4.33)
190
(7.48)
290
(11.42)
326
(12.83)
345
(13.58)
360
(14.17)
203
(7.99)
236
(9.29)
255
(10.04)
270
(10.63)
● Heat sink outside attachment (MR-(J)ACN)
By mounting the heat sink outside attachment on the converter unit or servo amplifier, the heat generating section can be mounted outside the
control box. This makes it possible to dissipate the unit’s heat to outside the box. Approx. 50% of the heating value can be dissipated with this
method, and the control box dimensions can be downsized.
● Line noise filter (FR-BSF01, FR-BLF)
This filter is effective in suppressing radio noise emitted from the servo amplifier’s or converter unit’s power-supply side or output
side and high-frequency leakage current (zero-phase current). Especially effective in the 0.5MHz to 5MHz band.
110 (4.33)
22 (0.87)
95 (3.74)
65 (2.56)
65 (2.56)
3 (0.12)
2-ø5 (0.197)
ø33
(1.299)
130 (5.12)
85 (3.35)
160 (6.30)
180 (7.09)
ø7 (0.276)
80 (3.15)
31.5 (1.24)
2.3 (0.09)
35
(1.378)
7 (0.276)
<FR-BSF01>
MR-J2S-200M or smaller
<FR-BLF>
MR-J2S-350M or larger
External dimensions
Unit: mm (inch)
Connections
NFB
Line noise
filter
Servo-amp
L1
L2
L3
MC
Power-
supply
L1
NFB MC
L2
L3
Converter
unit
Line noise filters
Power-
supply
Wind the 3-phase wires in the same direction the same number of winds, and then
connect to the power-supply side and output side of the servo amplifier or converter unit.
Increasing the number of winds on the power-supply side is effective, but normally, the
wire is wound approx. four times. If the wire is thick and hard to wind, use two or more
filters, and make sure that the total of penetrations exceeds the above number. Make sure
that the number of penetrations on the output side is four times or less. Do not wind the
grounding (earth) wire together with the 3-phase wires. The effect of the filter will drop.
MR-J2S-22KM(4) or smaller
MR-J2S-30KM(4) or larger
Blue
29 (1.14)
29 (1.14)
7
(0.28)
44 (1.73)
58 (2.28)
ø5 (0.197)
hole
Leakage current: 4mA
300 (11.8)
42 (1.65)
4 (0.16)
GreenRed
White