Specifications
Options
83
● Maintenance relay card (MR-J2CN3TM) ... Use with MR-J2S-700A/B/CP/CL or smaller
● Manual pulse generator (MR-HDP01) ... Compatible only with MR-J2S-CP type and MR-J2S-CL type.
(Note 1)
● External digital display (MR-DP60) ... Compatible only with MR-J2S-CP type and MR-J2S-CL type.
The maintenance relay card is used when using the personal computer and analog monitor output simultaneously.
Unit: mm (inch)
External dimensions
2-ø5.3 (0.209)
mounting hole
3 (0.118)
41.5 (1.63)
75 (2.95)
88 (3.46)
100 (3.94)
MR-J2CN3TM
CN3A CN3B CN3C
A1
B1
A6
B6
TE1
Notes:
1. Use the MR-J2HBUSMM for the maintenance relay card cable.
2. Use the connector CN4 and cable MR-H3CBL1M for the
MR-J2S-11KA(4)/B(4) or larger analog monitor output.
Note: Cannot be used with CC-Link compatible product (MR-J2S-MCP-S084).
Notes: 1. Cannot be used with CC-Link compatible product (MR-J2S-MCP-S084).
2. Manufacture the manual pulse generator cable with the optional CN1 connector (MR-J2CN1). Refer to “MR-J2S SERVO AMPLIFIER INSTRUCTION MANUAL” for details.
Notes: 1. When using the MR-DP60, change the parameter No. 16 value. Refer to “MR-J2S SERVO AMPLIFIER INSTRUCTION MANUAL” for details.
2. Manufacture the external digital display cable with the optional CN1 connector (MR-J2CN1). Refer to “MR-J2S SERVO AMPLIFIER INSTRUCTION MANUAL” for details.
Unit: mm (inch)
External dimensions
ø
6
2
(ø2
.4
4
1
)
+2
0
+0.079
0
ø72
(2.835 )
±
0.2
±
0.008
MANUAL
TYPE
SERIALNO.
ø50 (1.969)
ø70 (2.756)
ø60
±0.5
(2.362
±0.0197
)
3.6
(0.14)
Packing t2.0
16
(0.63)
20
(0.79)
27.0
±0.5
(1.06
±0.0197
)
ø80
±1
(3.15
±0.0394
)
Unit: mm (inch)
Mounting
Panel cutting
3-ø4.8 (0.189)
equally divided
Unit: mm (inch)
External dimensions
Unit: mm (inch)
Mounting
20 (0.79)
2-ø5 (0.197)
Front mounting Inside mounting
141 (5.55)
150 (5.91)
53 (2.09)
2-ø5 (0.197)
95 (3.74)
150 (5.906)
Square hole
Square hole
7.5 (0.295)
MITSUBISHI
7.5
(0.295)
150 (5.91)
165 (6.5)
MR-DP60
TB1
TB2
29 (1.14)
29 (1.14)
58 (2.28)
4 (0.16)
43 (1.69)
38 (1.496)
48 (1.89)
2-ø4.5 (0.177) mounting hole
2-ø6.5 (0.256) depth 1 (0.039)
The servomotor’s absolute value can be maintained by installing a battery in the servo-amp.
There is no need to install the battery when using as incremental mode.
Note: 1. A6BAT can be used also.
2. The 44th Edition of the IATA (International Air Transportation Association) Dangerous Goods
Regulations was effected in January 1st, 2003 and administered immediately.
In this edition, the provisions relating to lithium and lithium ion batteries have been revised to strengthen regulations on the
air transportation of battery.
This battery is not dangerous goods (not class 9). Therefore, these batteries of 24 units or less are not subject to the regulations.
● Battery (MR-BAT)
Nominal voltage
Nominal capacity
Lithium content
Type
MR-BAT
3.6V
1700mAh
0.48g
These batteries more than 24 units require packing based on Packing Instruction 903.
If you need the self-certification form for the battery safety test, contact Mitsubishi.
For more information, contact Mitsubishi. (as of August, 2003)
8.89 (0.35) 7.6 (0.299)
Only M3✕6 can be mounted
3-M4 stud L10
P.C.D 72 equally divided
12V 0V A B
5V
~
Mass
kg (lb)
Model