Specifications
82
External dimensions ConnectionsUnit: mm (inch)
Servo-amp
MR-J2S-11KA4/B4
to 22KA4/B4
Serial connection
(1.0m
3
/min, M92✕2)
Twist
Leave a space of 70mm
(2.76 inch) or more between
each resistor.
Model
Tolerable regenerative power (W)
500
850
850
Qty.
4
5
5
Resistance value (Ω)
20 (5Ω✕4)
12.5 (2.5Ω✕5)
10 (2Ω✕5)
Mass/unit kg (lb)
0.8 (1.8)
0.8 (1.8)
0.8 (1.8)
GRZG400-5Ω
GRZG400-2.5Ω
GRZG400-2Ω
With fan (W)
800
1300
1300
● GRZG400-5Ω, GRZG400-2.5Ω, GRZG400-2Ω: Standard accessory (Note 1, 5)
Model
Tolerable regenerative power (W)
1300
3900 (3 unit set)
Mass kg (lb)
10 (22)
11 (24.2)
MR-RB136-4
MR-RB138-4
● MR-RB136-4, MR-RB138-4
● MR-RB136-4
● MR-RB138-4
384 (15.12)
410 (16.14)
46 (1.81)
350 (13.78)
ø5.5 (0.216) hole Terminal
40 (1.57)
79 (3.11)
9 (0.35)
40 (1.57)
Notes:
1. Connect MR-RB136-4 to the converter unit.
2. Disconnect the short bar across P1-P2 when using the DC reactor.
Notes: 1. Connect MR-RB138-4 to the converter unit.
2. Disconnect the short bar across P1-P2 when using the DC reactor.
Servomotor
HA-LFS
Servomotor
thermal
Servomotor
thermal
OHS1
24VDC
power
OHS2
P1
P2
P
G3 G4
C
Optional
regeneration
unit fan
1-phase
400VAC
1-phase
400VAC
(Note 2)
Converter unit
DC reactor (option)
PC
RS
RA
(Note 2)
OHS1
OHS2
P1
P2
P
G3 G4
C
PC
RS
RA
G3 G4
PC
RS
G3 G4
PC
RS
✽Create an external sequence that
turns off the servo amplifier's main
circuit contactor contact when the
thermal protector contact (b
contact) in the optional
regeneration unit functions
(opens) due to overheating.
✽Create an external sequence that
turns off the servo amplifier's main
circuit contactor contact when the
thermal protector contact (b
contact) in the optional
regeneration unit functions
(opens) due to overheating.
2-ø10 (0.393) hole
230 (9.06)
260 (10.24)
15 (0.59)15 (0.59)
10 (0.39)
2.3 (0.09)
15 (0.59)
197 (7.76)
215 (8.46)
480 (18.9)
10
(0.39)
10 (0.39)
500 (19.69)
Fan
L1
L2
L3
U
V
W
P
P1
C
N
Do not disconnect the short bar.
● MR-RB6B-4, MR-RB60-4, MR-RB6K-4 (Note 5)
Model
MR-RB6B-4
MR-RB60-4
MR-RB6K-4
Tolerable
regenerative power (W)
500
850
850
10 (22)
11 (24.2)
11 (24.2)
Description
GRZG400-5Ω✕4
GRZG400-2.5Ω✕5
GRZG400-2Ω✕5
P
C
G3
G4
Optional regeneration unit
Servo-amp
MR-J2S-11KA4/B4
to 22KA4/B4
Create a sequence that shuts off
the main circuit power-supply when
the thermal protector activates.
COM
ALM
P
P1
C
RA
(Note)
800
1300
1300
With fan
(W)
Mass
kg (lb)
Do not disconnect the short bar.
Note: Create a sequence that turns OFF the magnetic contactor (MC)
when abnormal overheating occurs.
Servomotor
HA-LFS
Optional
regeneration
unit fan
Optional
regeneration
unit fan
Optional
regeneration
unit fan
Converter unit
DC reactor (option)
24VDC
power
● Optional regeneration unit
<Terminal arrangement>
Screw size: M5
G4 G3 C PR400 S400
Notes:1.
2.
3.
4.
5.
A servo amplifier (MR-J2S-MKM4-PX) without enclosed regenerative resistor is available for the servo amplifiers MR-J2S-11KA4/B4 to 22KA4/B4.
The optional regeneration unit will heat up to approx. 100°C (212°F), so do not directly mount it on a wall susceptible to heat. Use nonflammable wires or provide flame resistant
treatment (use silicon tubes, etc.), and wire so that the wires do not contact the optional regeneration unit.
Always use twisted wires for the optional regeneration unit, and keep the length as short as possible (5m (16.4 ft) or less).
Always use twisted wires for the temperature detector, and make sure that the detector does not malfunction due to inducted noise.
When installing cooling fans (approx. 1.0m
3
/min, M92 x 2 units) to increase the regeneration braking frequency, change parameter No. 0 (for MR-J2S-A type) or No. 2 (for MR-J2S-B type).
<Terminal arrangement>
G3G4 PC
Screw size: M5
TE1
2-ø10 (0.393)
mounting hole
30 (1.18) 30 (1.18)
215 (8.46)
260 (10.24)
230 (9.06)
15 (0.59)
230 (9.06)
2.3 (0.09)
500 (19.69)
480 (18.9)
10 (0.39) 10 (0.39)
440 (17.32)
TE1
Options