Specifications

Peripheral Equipment (MR-J2S-MCP)
55
Connections with peripheral equipment
Peripheral equipment is connected to the MR-J2S-CP as described below.
Connectors, options, and other necessary equipment are available so that users can set up the MR-J2S-CP easily and begin using it right away.
RST
CN1A
CN1B
CN3
TE2
UVW
CN2
XY
L21
D
C
P
L11
Z
L1
L2
L3
Used to protect the power
supply line.
No-fuse circuit
breaker (NFB)
Power-supply
3-phase 200-230VAC
or
1-phase 230VAC
(Note 1)
Used to turn off the servo-
amps power when an alarm
has been triggered.
Magnetic contactor
(MC)
Power factor
improvement
reactor
(FR-BAL)
<With front cover open>
Control signal (option)
CN3 for RS-232C communication (option)
CN3 for RS-422 communication (option)
Regeneration unit (option)
Install this unit in situations involving
frequent regeneration and large load
inertia moments. Connect this unit
referring to Standard Wiring Diagram.
HC- FS servomotor and encoder
(Above picture is HC-KFS23.)
Battery compartment (option)
Display panel
Setting section
A battery (MR-BAT) is installed in the holder when
using as an absolute system. Not required when
using as an incremental system.
Displays monitoring data, parameters,
and alarms.
Parameter settings and monitoring
etc. are executed with push buttons.
Control signal
connector
(Note 4)
Servo amplifier
MR-J2S- CP
Junction terminal block (MR-TB20)
All signals can be connected easily
at this terminal block without a
connection to CN1A or CN1B.
Manual pulse generator
(MR-HDP01)
(Note 2)
(Note 3)
(Note 2)
MR Configurator (Setup software)
MRZJW3-SETUP 151E or later
External digital display (MR-DP60)
Type 3 ground or above
Notes: 1. If a 1-phase power-supply (230VAC) is used, please connect to terminals L1 and L2. Nothing should be connected to L3.
2. RS-232C and RS-422 are mutually-exclusive features. RS-422 communication is possible with parameter switching.
The RS-422 communication cable can be made by using the optional CN1 connector (MR-J2CN1).
3. The manual pulse generator cable can be made by using the optional CN1 connector (MR-J2CN1).
4. The connection with the peripheral devices shown above is for the MR-J2S-350CP or smaller. Connect the MR-J2S-500CP or larger as shown in the standard connection diagram.