Specifications
Specifications and Characteristics
15
HA-LFS 1500r/min series servomotor specifications
HA-LFS 1500r/min series servomotor torque characteristics
Speed (r/min)
500 1000 20001500
150
100
50
0
Speed (r/min)
500 1000 20001500
240
160
80
0
Speed (r/min)
500 1000 20001500
300
200
100
0
Speed (r/min)
500 1000 20001500
400
200
300
100
0
Speed (r/min)
500 1000 20001500
600
400
200
0
Speed (r/min)
500 1000 20001500
600
400
200
0
Peak running
range
Continuous running
range
Peak running
range
Continuous running
range
Peak running
range
Continuous running
range
Peak running
range
Continuous running
range
Peak running
range
Continuous running
range
Peak running
range
Continuous running
range
21000
14000
7000
0
Torque (oz
•
in)
Torque (N
•
m)
HA-LFS701M (B) (Note 1)
84000
56000
28000
0
Torque (oz
•
in)
Torque (N
•
m)
HA-LFS30K1M (Note 1)
33600
22400
11200
0
Torque (oz
•
in)
Torque (N
•
m)
HA-LFS11K1M (B) (Note 1)
42000
28000
14000
0
Torque (oz
•
in)
Torque (N
•
m)
HA-LFS15K1M (B) (Note 1)
56000
28000
42000
14000
0
Torque (oz
•
in)
Torque (N
•
m)
HA-LFS22K1M (Note 1)
84000
56000
28000
0
Torque (oz
•
in)
Torque (N
•
m)
HA-LFS37K1M (Note 1)
Notes:
1. Solid lines show torque characteristics for 3-phase
200VAC operation.
2. Solid lines show torque characteristics for 3-phase
400VAC operation.
Notes:1.
2.
3.
4.
5.
Make sure that the effective torque is less than 75% of the 37kW capacity during the power factor improvement. Always use a DC reactor (MR-DCL37K).
The power facility capacity varies depending on the power supply's impedance.
The regenerative brake frequency shows the permissible frequency for decelerating a stand-alone motor from rated speed to a stop. When under load, however, the value becomes
the table value divided by (m+1) where m is the load inertia moment divided by the motor inertia moment. When the rated speed is exceeded, the regenerative brake frequency is
inversely proportional to the square of (Operating speed/rated speed). When the operating speed varies with the frequency or when regeneration is constant (as with vertical feeds),
find the regeneration heat generated (W) while operating and do not exceed the permissible value.
Install a cooling fan (approx. 1.0m
3
/min, M92).
The values apply when the parameter No.0 (for MR-J2S-A type) or No.2 (for MR-J2S-B type) is changed, and the cooling fans (approx. 1.0m
3
/min, M92 x 2 units) are installed.
Models
Specifications
Servomotor
Power facility capacity (Note 2) (kVA)
Continuous
running duty
Maximum torque (N·m [oz·in])
Rated speed (r/min)
Maximum speed (r/min)
Permissible instantaneous speed (r/min)
Power rate at continuous rated torque (kW/s)
Rated current (A)
Maximum current (A)
With no options
MR-RB31 (300W)
MR-RB51 (500W) (Note 4)
GRZG400-2Ω (4),
MR-RB65 (800W) (Note 5)
GRZG400-1Ω (5),
MR-RB66 (1300W) (Note 5)
GRZG400-0.8Ω (5),
MR-RB67 (1300W) (Note 5)
MR-RB139 (1300W)
MR-RB137 (3900W)
GRZG400-5Ω (4),
MR-RB6B-4 (800W) (Note 5)
GRZG400-2.5Ω (5),
MR-RB60-4 (1300W) (Note 5)
GRZG400-2Ω (5),
MR-RB6K-4 (1300W) (Note 5)
MR-RB136-4 (1300W)
MR-RB138-4 (3900W)
Standard
With electromagnetic brake
Cooling fan
701M (B)
700A/B/CP/CL
-U059
—
10
7
44.6 (6315.4)
134 (18974.4)
189
37
111
70
124
206
—
—
—
—
—
—
—
—
—
—
105 (574.0)
113 (617.7)
16
11
70.0 (9912)
210 (29736)
223
65
195
—
—
—
158
—
—
—
—
—
—
—
—
—
220 (1202.7)
293 (1601.7)
22
15
95.5 (13522.8)
286 (40497.6)
309
87
261
—
—
—
—
191
—
—
—
—
—
—
—
—
295 (1612.6)
369 (2017.2)
22K1M
22KA/B
(Note 9)
—
33
22
140 (19824)
350 (49560)
357
126
315
—
—
—
—
—
102
—
—
—
—
—
—
—
550 (3006.6)
—
48
30
191 (27045.6)
477 (67543.2)
561
174
435
—
—
—
—
—
—
87
260
—
—
—
—
—
650 (3553.3)
—
59
37
236 (33417.6)
589 (83402.4)
514
202
505
—
—
—
—
—
—
52
156
—
—
—
—
—
1080 (5903.9)
—
11K1M (B)
15K1M (B)
30K1M 37K1M (Note 1)
11KA/B (Note 9)
—
15KA/B (Note 9)
—
30KA/B (Note 9) 37KA/B-U042
1500
2000
2300
Less than 10-times the servomotor’s inertia moment (Note 6)
Resolution per encoder/servomotor rotation: 131072 p/rev
17 bit encoder, oil seal
Totally enclosed ventilated (protection degree: IP44)
0 to 40°C (32 to 104°F) (non freezing), storage: –15 to 70°C (5 to 158°F) (non freezing)
80% RH max. (non condensing), storage: 90% RH max. (non condensing)
Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist, or dust
1000 meters or less above sea level
X: 11.7m/s
2
Y: 29.4m/s
2
X: 9.8m/s
2
Y: 9.8m/s
2
55 (121.2)
70 (154.2)
95 (209.3)
126 (277.6)
115 (253.4)
146 (321.7)
160 (352.5)
—
180 (396.6)
—
230 (506.7)
—
Single phase 200 to 220VAC/50Hz
Single phase 200 to 230VAC/60Hz
42 (50Hz)/
54 (60Hz)
0.21 (50Hz)/
0.25 (60Hz)
3-phase 200 to 220VAC/50Hz
3-phase 200 to 230VAC/60Hz
32 (50Hz)/
40 (60Hz)
0.30 (50Hz)/
0.25 (60Hz)
45 (50Hz)/
63 (60Hz)
0.32 (50Hz)/
0.35 (60Hz)
120 (50Hz)/
175 (60Hz)
0.65 (50Hz)/
0.80 (60Hz)
Servomotor series
HA-LFS 1500r/min series (Low inertia, medium capacity to large capacity)
Servomotor model HA-LFS
Servo-amp model MR-J2S-
(Note 8)
Converter unit model
Recommended load/motor inertia moment ratio
Speed/position detector
Attachments
Structure
Ambient temperature
Ambient humidity
Atmosphere
Elevation
Vibration (Note 7)
Environment
Mass
(kg [lb])
Power
Voltage, frequency
Input (W)
Standard
With electromagnetic brake
Rated current (A)
Regeneration
braking
frequency
(times/min)
(Note 3)
Moment of inertia
J (×10
-4
kg·m
2
)
[J (oz·in
2
)]
Rated output (kW)
Rated torque (N·m [oz·in])
MR-HP30KA