Specifications
9
MITSUBISHI ELECTRI
C
MELSERVO MR-J2S
SYSTEM DESCRIPTION
BASICS
MITSUBISHI
Connections with Peripheral Equipment
Peripheral equipment is connected to the
MR-J2-Super as shown below.
Connectors, options, and other necessary
equipment are available to allow users to
easily to setup the MR-J2S and begin using
it right away.
Power supply
Upper controller
(connector CN1A)
No-fuse
circuit
breaker
(NFB)
Magnetic
contactor
(MC)
Servo motor and encoder (connector CN2)
햹 Junction terminal block
(optional)
Servo motor power lead
Encoder cable
MR-J2S servo amplifier MR-J2S-앮A
Display panel
Setting section
Battery compartment
햺 Control signal
(optional/for operation panel;
connector CN1B)
Control
circuit terminal
block
햻 RS232C/RS422
communications
(optional;
connector CN3)
MR-J2 servo amplifier MR-J2S-앮A
앬
Display panel
Displays monitoring data, parameters,
and alarms.
앬
Setting section
Parameter settings are performed with
push buttons, and monitoring data is
displayed.
앬
Charge lamp
Goes on when the main circuit power
supply is on. Do not plug/ unplug
power lines when this light is on.
앬
Battery compartment
A battery (A6BAT) can be optionally
installed in the holder if used as an
absolute system (not required if used as
an incremental system).
Servo motor and encoder
(connector CN2)
Control circuit terminal block
Used to connect the control circuit power
supply and the regenerative brake option.
Power supply
3~, 200–230 V AC
1~, 230 V AC for Servo Drives ≤ 750 W
No-fuse circuit breaker (NFB)
Used to protect the power supply line.
Magnetic contactor (MC)
Used to turn OFF the power of the servo
amplifier when an alarm has been triggered.
Upper controller
(connector CN1A)
The J2 can be connected to any pulse train
output controller (e.g. FX2N-10GM/-20GM,
FX2N-1PG, A(1S)D75첸, QD75P첸).
햹 Junction terminal block
(optional)
All signals can be connected at this
junction terminal block.
햺 Control signal (optional/ for opera-
tion panel; connector CN1B)
Connects to the I/O port of the PLC or to
the operation panel of the machine.
햻 RS232C/RS422 communications
(optional; connector CN3)
Connects the unit to a personal computer,
enabling the user to perform monitoring,
batch parameter entry and saving, graph
display, test operation and advanced
setup features.
Dedicated cables and setup software are
also available.
EMC filter