MELSERVO J2-Super 4 - 11
4.5 Parameter
When the servo amplifier is connected with the servo system controller, the parameters are set
to the values of the servo system controller. Switching power off, then on makes the values set
on the setup-software invalid and the servo system controller values valid.
4.5.1 Parameter write inhibit
The release of access to the parameters is established via parameter 40 (parameter write
protection). Parameter No. 40 is made valid by switching power off, then on after setting its
value.
The following table provides an overview over the settings of parameter No. 40:
NOTES In the maker setting parameters, do not set any values other than the initial values.
Setting may not be made to some parameters and ranges depending on the model or
version of the servo system controller. For details, refer to the servo system controller user's
manual.
Setting Function Operation from controller Operation from setup-software
0000
(Initial value)
Read
Parameter No. 1 to No. 39 Parameter No. 1 to No. 11 and No. 40
Write
000A
Read
Parameter No. 1 to No. 39 Parameter No. 40
Write
000C
Read
Parameter No. 1 to No. 39
Parameter No. 1 to No. 40
Write Parameter No. 1 to No. 11 and No. 40
000E
Read
Parameter No. 1 to No. 39 Parameter No. 1 to No. 40
Write
100E
Read
Parameter No. 1 to No. 39
Parameter No. 1 to No. 40
Write Parameter No. 40
Tab. 4-11: Parameter settings