Instruction manual
Operation Test operation mode
4 - 8
● Positioning operation
Positioning operation can be performed without using the servo system controller. This
operation may be used independently of whether the servo is on or off and whether the servo
system controller is connected or not.
Exercise control on the positioning operation screen of the setup-software.
● Program operation
Program operation can be performed in two or more operation patterns combined, without using
the servo system controller. This operation may be used independently of whether the servo is
on or off and whether the servo system controller is connected or not.
Exercise control on the programmed operation screen of the setup-software..
Name Initial value Setting range
Travel [pulse] 131072 0 to 9999999
Speed [r/min] 200 0 to 5175
Acceleration/deceleration time constant [ms] 1000 0 to 20000
Tab. 4-7: Positioning operation settings
Function Button
Forward rotation start Forward
Reverse rotation start Reverse
Pause Pause
Tab. 4-8: Operation method
Function Button
Start Start
Stop Reset
Tab. 4-9: Operation method