Instruction manual

Points to check prior to starting operation Operation
MELSERVO J2-Super 4 - 1
4 Operation
4.1 Points to check prior to starting operation
Wiring
Before starting operation, check the following:
A correct power supply is connected to the power input terminals (3-phase: L1, L2, L3,
1-phase: L11, L21) of the servo amplifier.
The servo motor power supply terminals (U, V, W) of the servo amplifier match in phase
with the power input terminals (U, V, W) of the servo motor.
The servo motor power supply terminals (U, V, W) of the servo amplifier are not shorted to
the power input terminals (L1, L2, L3) of the servo motor.
Ground the servo amplifier and servo motor securely.
When using a regenerative brake option or brake unit:
always remove the lead across the terminals D and P for the servo amplifier MR-J2S-
350B or less and MR-J2S-200B4 or less.
disconnect the cable connections to the internal brake resistor between the terminals P
and C for the servo amplifier MR-J2S-500B or more and MR-J2S-350B4 or more.
S001257C
Fig. 4-1: Wiring
S000582C
Fig. 4-2: Short circuit
MR-J2S- B
M
U
U
V
V
W
W
L1
L2
L3
L11
L21
M
U
U
V
V
W
W
L1
L2
L3
L11
L21
MR-J2S- B MR-J2S- B4
M
U
U
V
V
W
W
L1
L2
L3
L11
L21
24 V DC
+
1-phase connector 3-phase connector3-phase connector
Servo amplifier 200V Servo amplifier 400VServo amplifier 200V
M
U
V
W
L1
L2
L3
Servo amplifier