Instruction manual

Servo motor with electromagnetic brake Connection
MELSERVO J2-Super 3 - 21
3.7 Servo motor with electromagnetic brake
Connection diagram
Please observe closely the following instructions for the use of a servo motor with
electromagnetic brake.
Provide a separate power source of 24VDC for the electromagnetic brake.
The brake will operate when the power switches off.
Switch off the SON command after the servo motor has stopped.
b
CAUTION:
Configure the electromagnetic brake circuit so that it is activated not only by the
interface unit signals but also by a emergency stop.
b
CAUTION:
The electromagnetic brake is only intended for holding a static load, e.g. from vertical
lifting axes. The braking effect and frequent switching of the EMERGENCY OFF
function will result in the destruction of the brake after only a few cycles.
S000982C
Fig. 3-22: Connection diagram
M
EM1 RA
Emergency stop signal
Contacts must be open when servo ON,
when an alarm occurence and when an
electromagnetic brake interlock
Servo motor
Electro-
magnetic brake
B2
MBR
COM
VDD
RA
RA
24VDC
M
B1
EM1
Servo amplifier
Servo motor