Instruction manual
General environmental conditions Installation
MELSERVO J2-Super 2 - 1
2 Installation
2.1 General environmental conditions
b
CAUTION:
●
The equipment must be installed in the specified direction. Otherwise, a fault may
occur.
●
Leave specified clearances between the servo amplifier and control box inside
walls or other equipment.
Environmental conditions
Data
Servo amplifier Servo motor
Ambient temperature during operation 0 to +55°C (non-freezing) 0 to +40°C (non-freezing)
Ambient humidity during operation Max. 90% (no condensation) Max. 80% (no condensation)
Ambient temperature in storage −20 to +65°C −15 to +70°C
Ambient humidity in storage Max. 90% (no condensation) Max. 90% (no condensation)
Ambience Indoors (no direct sunlight); no corrosive gas, no inflammable gas, no oil
mist, no dust)
Altitude above sea level Max. 1000m
Protective structure IP00 HC-KFS/MFS: IP55,
HC-SFS/RFS: IP65
Vibration Max. 5.9m/s² (0,6 g) Section 2.1.2
Tab. 2-1: Environmental condition overview