Instruction manual

Introduction Operating elements
1 - 18
S001198C
Fig. 1-22: Servo amplifier MR-J2S-60B4 to MR-J2S-200B4
No. Name Description Reference
Main circuit connector (CNP1) Used to connect the input power supply Section 3.1.3
Bus cable connector (CN1A) Used to connect the servo system controller
or preceding axis servo amplifier.
Section 3.1.3
Bus cable connector (CN1B) Used to connect the subsequent axis servo
amplifier or termination connector
(MR-A-TM)
Section 3.1.3
Encoder connector (CN2) Used for connection of the servo motor
encoder.
Section 3.1.3
Communication connector (CN3) Used to connect a personal computer or
output analog monitor data.
Section 3.1.3
Name plate Section 1.3.3
Regeneration connector Used to connect the regeneration brake
option.
Control circuit terminal block (CN4) Used to connect the control circuit power
supply.
Section 3.1.2
Motor power supply connector
(CNP3)
Used to connect the servo motor Section 3.1.2
Protective earth terminal (PE) Module grounding Section 3.4
Fan
Tab. 1-6: Operating elements and their meaning
b
CAUTION:
Any mixing up of the connectors CN1A, CN1B, CN2 and CN3 can lead to a shortcircuit
and damage to the inputs and outputs.