Instruction manual

Characteristics Specifications
MELSERVO J2-Super 10 - 5
Electromagnetic brake power supply
24VDC of the internal power output for interface (VDD) cannot be used. Prepare the following
power supply for use with the electromagnetic brake only. Examples for the connection of the
brake are shown in the following diagrams:
S000656C
Fig. 10-4:
Brake unit connection
28VAC
24VDC
T
T
VAR
VAR
28VAC
Electromagnetic
brake
Electromagnetic
brake
Electromagnetic
brake
T : Transformer
VAR : Surge absorber
(a)
(b)
(c)