Instruction manual
Operation Parameter
4 - 14
4.5.3 Parameter description:
Number Symbol Initial value Unit Setting range
1 AMS 0000 Refer description
Amplifier setting
Used to select the absolute position detection.
2 REG 0000 Refer description
Regenerative brake resistor
CAUTION:
Wrong setting may cause the regenerative brake option to burn.
NOTE:
If the regenerative brake option selected is not for use with the servo amplifier, parameter error (37) occurs.
3 0080
Reserved
Do not change this parameter.
4 0000
Reserved
Do not change this parameter.
5 1
Reserved
Do not change this parameter.
Tab. 4-13: Parameter list details (1)
0 00
Positioning
0: Standard (incremental)
1: Absolute position detection system
00
00
Regenerative selection brake option
00: No brake resistor
01: FR-RC, FR-BU
05: MR-RFH220-40
08: MR-RFH400-13
09: MR-RFH400-13
0B: MR-RFH400-6.7
0C: MR-RFH400-6.7
10: MR-RFH75-40
11: MR-RFH75-40
Servo amplifier 200V
Regenerative selection brake option
00: No brake resistor
01: FR-RC-H , FR-BU-H
80: MR-RB3H-4
81: MR-RB5H-4/MR-PWR-T-600-80
82: MR-RB3G-4
83: MR-RB5G-4/MR-PWR-T-600-47
84: MR-RB34-4
85: MR-RB54-4/MR-PWR-T-600-26
86: MR-RB1L-4/MR-PWR-T-150-270
87: MR-RB3M-4/MR-PWR-T-400-120
Servo amplifier 400V