Specifications
Options
81
External dimensions ConnectionsUnit: mm (inch)
● MR-RB3M-4, MR-RB3H-4, MR-RB3G-4, MR-RB34-4
● MR-RB1L-4
● MR-RB5H-4, MR-RB5G-4, MR-RB54-4
Model
2.9 (6.4)
2.9 (6.4)
2.9 (6.4)
2.9 (6.4)
Mass kg (lb)
MR-RB3M-4
MR-RB3H-4
MR-RB3G-4
MR-RB34-4
Model
5.6 (12.3)
5.6 (12.3)
5.6 (12.3)
Mass kg (lb)
MR-RB5H-4
MR-RB5G-4
MR-RB54-4
82.5
(3.25)
350 (13.78)
162.5 (6.4)
12.5
(0.49)
12.5
(0.49)
162.5 (6.4)
133 (5.24)
49
(1.93)
2.3 (0.09)
23 (0.91)
12
(0.47)
7 (0.28)
120 (4.72)
8 (0.31)
30 (1.18)
223 (8.78)
82.5
(3.25)
Fan mounting screw
2-M3 screw
provided on opposite side
7 ✕ 14 (0.276 ✕ 0.551)
long hole
Wind blows in
direction of arrow
Fan
Always disconnect the wire for the servo
amplifier's built-in regenerative resistor
(across P-C).
Servo amplifier
P
C
P
C
G3
G4
Optional
regeneration unit
(Note 2)
(Note 1)
5m (16.4ft) or less
● Optional regeneration unit
<Terminal arrangement>
G4
G3
C
P
Terminal screw size: M3
TE1
<Terminal arrangement>
G4
G3
C
P
Terminal screw size: M4
Mounting screw size: M6
<Terminal arrangement>
G4
G3
C
P
Terminal screw size: M4
● MR-J2S-200A4/B4 or smaller
● MR-J2S-350A4/B4 to 700A4/B4
Type
MR-RB1L-4
Mass
kg (lb)
1.1 (2.4)
Servo amplifier
5m (16.4ft) or less
(Note2)
(Note1)
Fan
Optional
regeneration unit
Always disconnect the wire across P-D.
D
P
P
C
G3
G4
C
Notes: 1.
2.
When using the MR-RB5H-4, always forcibly cool with a
cooling fan (approx. 1.0m
3
/min, M92). The cooling fan
must be ordered by user.
Create a sequence that turns off the magnetic contactor
(MC) when abnormal overheating occurs.
Notes: 1.
2.
When using the MR-RB5G-4 or MR-RB54-4, always forcibly cool
with a cooling fan (approx. 1.0m
3
/min, M92). The cooling fan
must be ordered by user.
Create a sequence that turns off the magnetic contactor (MC)
when abnormal overheating occurs.
TE1
6 (0.24)
6 (0.24)
156 (6.14)
6 (0.24)
168 (6.61)
36 (1.42)
40 (1.57)
15 (0.59)
144 (5.67)
149 (5.87)
2 (0.08)
6 (0.24)
173 (6.81)
24 (0.94)
ø6 (0.236)
mounting hole
Mounting screw size: M5
Mounting screw size: M6
Fan mounting screw
2-M3 screw
8.5
(0.33)
8.5
(0.33)
150 (5.91)
142 (5.59)
125 (4.92)
79 (3.11)
7 (0.28)
90 (3.54)
100 (3.94)
10 (0.39)
23 (0.91)
318 (12.52)
341 (13.43)
G4 G3 C P
Notes:1.
2.
The optional regeneration unit will heat up to approx. 100°C (212°F), so do not directly mount it on a wall susceptible to heat. Use nonflammable wires or provide flame resistant
treatment (use silicon tubes, etc.), and wire so that the wires do not contact the optional regeneration unit.
Always use twisted wires for the optional regeneration unit, and keep the length as short as possible (5m (16.4ft) or less).