Specifications

Options
80
Optional regeneration unit/tolerable regenerative power (W)
MR-RB
032
30
30
30
30
30
30
12
100
100
100
100
100
30
300
300
300
31
300
32
300
300
50
500
500
500
51
500
65
500 (800)
66
850 (1300)
67
850 (1300)
139
1300
1300
137
3900
3900
100
300
6B-4
500 (800)
60-4
850 (1300)
6K-4
850 (1300)
136-4
1300
1300
1300
1300
138-4
3900
3900
3900
3900
40
40
40
40
40
40
13
13
13
6.7
8
5
4
1.3 (Note 3)
1.3 (Note 3)
270
120
80
47
47
26
20
12.5
10
5 (Note 3)
5 (Note 3)
5 (Note 3)
5 (Note 3)
Resist-
ance
value
()
3H-4
300
3G-4
300
300
34-4
300
5H-4
500
5G-4
500
500
54-4
500
1L-4 3M-4
External dimensions Connections
Unit: mm (inch)
Servo motor
HA-LFS
Servo motor
HA-LFS
Servo motor
thermal
Servo motor
thermal
OHS1
Power supply
24VDC
Power supply
24VDC
OHS2
P1
P2
P
G3 G4
C
Optional
regeneration
unit fan
1-phase
200VAC
1-phase
200VAC
(Note 2)
Converter unit
Converter unit
DC reactor
(option)
DC reactor
(option)
PC
RS
RA
+
OHS1
OHS2
P1
P2
P
G3 G4
C
(Note 2)
PC
RS
RA
+
G3 G4
PC
RS
G3 G4
PC
RS
Model
Tolerable regenerative
power (W)
1300
3900 (3 units are required.)
Mass
kg (lb)
10 (22)
11 (24.2)
MR-RB139
MR-RB137
MR-RB139, MR-RB137
MR-RB139
MR-RB137
Create an external sequence that
turns off the servo amplifiers
main circuit contactor contact
when the thermal sensor contact
(b contact) in the optional regen-
eration unit functions (opens)
due to overheating.
Create an external sequence that
turns off the servo amplifiers main
circuit contactor contact when the
thermal sensor contact (b contact) in
the optional regeneration unit
functions (opens) due to overheating.
Note: By installing the thermal sensor,
create a safety circuit that shuts
off the main circuit power supply
when abnormal overheating oc-
curs.
2-ø10 (0.394)
hole
230 (9.06)
TE1
260 (10.24)
15
(0.59)
15 (0.59)
10 (0.39)
2.3 (0.09)
15 (0.59)
197 (7.76)
215 (8.46)
480 (18.9)
10
(0.39)
10
(0.39)
500 (19.69)
Servo amplifier
MR-J2S-11KA/B
to 22KA/B
Servo amplifier
MR-J2S-11KA/B
to 22KA/B
Serial connection
(1.0m
3
/min, M922 units)
Twist
Leave a space of 70mm (2.76 inch)
or more between each resistor.
Model
Tolerable regenerative
power (W)
500
850
850
Qty.
4
5
5
Resistance
value ()
8 (24)
5 (15)
4 (0.85)
Mass/unit
kg (lb)
0.8 (1.8)
0.8 (1.8)
0.8 (1.8)
GRZG400-2
GRZG400-1
GRZG400-0.8
With fan
(W)
800
1300
1300
GRZG400-2, GRZG400-1, GRZG400-0.8:Standard
accessory
(Note 3, 5)
384 (15.12)
410 (16.14)
46 (1.81)
350 (13.78)
ø5.5 (0.217) hole
Terminal
40 (1.57)
79 (3.11)
9
(0.35)
40 (1.57)
Fan
L1
L2
L3
U
V
W
P
P1
C
N
Do not disconnect the short bar.
MR-RB65, MR-RB66, MR-RB67 (Note 3, 5)
P
C
G3
G4
Optional
regeneration unit
Create a circuit that shuts off
the main circuit power supply when
the thermal sensor activates.
COM
ALM
P
P1
C
RA
Note: Create a sequence that turns off the magnetic contactor (MC) when abnormal overheating occurs.
Notes: 1. Connect MR-RB139 to the converter unit.
2. Disconnect the short bar across P1P2 when using the DC
reactor.
Notes: 1. Connect MR-RB137 to the converter unit.
2. Disconnect the short bar across P1P2 when using the DC
reactor.
(Note)
Do not disconnect the short bar.
Optional
regeneration
unit fan
Optional
regeneration
unit fan
Optional
regeneration
unit fan
3. The servo amplifier (MR-J2S-MKM-PX) without enclosed regenerative resistor is available for the servo amplifiers MR-J2S-11KA/B to 22KA/B.
4. Always use twisted wires for a thermal sensor, and make sure that the sensor does not fail to work properly due to inducted noise.
5. When increasing the regeneration braking frequency, install cooling fans (approx. 1.0m
3
/min, M922 units) and change the parameter No. 0 (for MR-J2S-A type) or No. 2 (for MR-J2S-B
type). The cooling fan must be ordered by user.
<Terminal arrangement>
G4 G3 C P
Terminal screw size: M5
TE1
<Terminal arrangement>
G4 G3 CSRP
Terminal screw size: M5
Note: 3 units of MR-RB137 are
required for each amplifier.
TE1
Model Description
Tolerable regenerative
power (W)
MR-RB65
MR-RB66
MR-RB67
500
850
850
800
1300
1300
10 (22)
11 (24.2)
11 (24.2)
GRZG400-24
GRZG400-15
GRZG400-0.85
With fan
(W)
Mass
kg (lb)
2-ø10 (0.394)
mounting hole
30 (1.18)
30
(1.18)
215 (8.46)
260 (10.24)
230 (9.06)
TE1
15 (0.59)
230 (9.06)
2.3 (0.09)
500 (19.69)
480 (18.9)
10 (0.39)
10
(0.39)
440 (17.32)
Mounting screw size: M5
Mounting screw size: M8
Mounting screw size: M8
3. As for MR-RB137 or MR-RB138-4, this is the value when 3 regeneration units are connected.