Specifications

Options
79
Optional regeneration unit
Servo amplifier model
(MR-J2S-)
Built-in
regenerative resistor/
tolerable regenerative
power (W)
Standard accessory (external regenerative resistor)/tolerable regenerative power (W)
GRZG400-
10A(1)/B(1)/CP(1)/CL(1)
20A(1)/B(1)/CP(1)/CL(1)
40A(1)/B(1)/CP(1)/CL(1)
60A/B/CP/CL
70A/B/CP/CL(-UM)
100A/B/CP/CL
200A/B/CP/CL
350A/B/CP/CL
500A/B/CP/CL
700A/B/CP/CL
11KA/B
15KA/B
22KA/B
30KA/B
37KA/B
60A4/B4
100A4/B4
200A4/B4
350A4/B4
500A4/B4
700A4/B4
11KA4/B4
15KA4/B4
22KA4/B4
30KA4/B4
37KA4/B4
45KA4/B4
55KA4/B4
10
10
10
20
20
100
100
130
170
10
20
100
100
130
170
54
500 (800)
2.55
850 (1300)
25
850 (1300)
24
500 (800)
15
850 (1300)
0.85
850 (1300)
ø6 (0.236)
mounting hole
LA
LB
LD
1.6 (0.06)
LC
6 (0.24)
TE1
6 (0.24)
156 (6.14)
12 (0.47) 144 (5.67)
6 (0.24)
168 (6.61)
12 (0.47)
20
(0.79)
5
(0.20)
Type
MR-RB032
MR-RB12
Variable dimensions
LA
30 (1.18)
40 (1.57)
LB
15 (0.59)
15 (0.59)
LC
119 (4.69)
169 (6.65)
LD
99 (3.90)
149 (5.87)
Mass
kg (lb)
Mass
kg (lb)
Mass
kg (lb)
0.5 (1.1)
1.1 (2.4)
Type
MR-RB30
MR-RB31
MR-RB32
2.9 (6.4)
2.9 (6.4)
2.9 (6.4)
Type
MR-RB50
MR-RB51
5.6 (12.3)
5.6 (12.3)
Servo amplifier
5 m (16.4ft) or less
(Note 2)
(Note 2)
(Note 1)
(Note 1)
Fan
Fan
Optional
regeneration unit
Always disconnect the wire across P-D.
D
P
P
C
G3
G4
C
Notes: 1.
2.
When using the MR-RB50, always forcibly cool with
a cooling fan (approx. 1.0m
3
/min, M92). The cooling
fan must be ordered by user.
Create a sequence that turns off the magnetic
contactor (MC) when abnormal overheating occurs.
Notes: 1.
2.
When using the MR-RB50 and MR-RB51, always
forcibly cool with a cooling fan (approx. 1.0m
3
/min,
M92). The cooling fan must be ordered by user.
Create a sequence that turns off the magnetic
contactor (MC) when abnormal overheating occurs.
5 m (16.4ft) or less
Optional
regeneration unit
P
P
G3
G4
C
C
Servo amplifier
Always disconnect the wire for the servo
amplifier's built-in regenerative resistor
(across P-C).
External dimensions ConnectionsUnit: mm (inch)
MR-RB032, MR-RB12 MR-RB30, MR-RB31, MR-RB32
MR-J2S-350M or smaller
MR-J2S-500M, 700M
MR-RB50, MR-RB51
<Terminal arrangement>
G4
G3
C
P
Terminal screw size: M3
Mounting screw size: M5
TE1
<Terminal arrangement>
G4
G3
C
P
Terminal screw size: M4
<Terminal arrangement>
G4
G3
C
P
Terminal screw size: M4
Notes: 1. The optional regeneration unit will heat up to approx. 100°C (212°F), so do not directly mount it on a wall susceptible to heat. Use nonflammable wires or provide flame resistant
treatment (use silicon tubes, etc.), and wire so that the wires do not contact the optional regeneration unit.
2. Always use twisted wires for the optional regeneration unit, and keep the length as short as possible (5m (16.4ft) or less).
Mounting screw size: M6
Mounting screw size: M6
8.5
(0.33)
8.5
(0.33)
125
(4.92)
79 (3.11)
150 (5.91)
142 (5.59)
7 (0.28)
90 (3.54)
100 (3.94)
10 (0.39)
17 (0.67)
318 (12.52)
335 (13.19)
Fan mounting screw
2-M3 screw
G4 G3 C P
Fan mounting screw
2-M3 screw
provided on
opposite side
82.5
(3.25)
350 (13.78)
162.5 (6.4)
12.5
(0.49)
12.5
(0.49)
162.5 (6.4)
133 (5.24)
49
(1.93)
2.3
(0.09)
17
(0.67)
200 (7.87)
12
(0.47)
7 (0.28)
120 (4.72)
8 (0.31)
30 (1.18)
108 (4.25)
217 (8.54)
82.5
(3.25)
7 14
(0.276 0.551)
long hole
G4G3CPG4G3CP
Wind blows
in direction
of arrow
Notes: 1. The tolerable regenerative power in the table differs from the regenerative resistors rated wattage.
2. For the values given in parentheses, install cooling fans (approx. 1.0m
3
/min, M922 units), and change the parameter No. 0 (for MR-J2S-A type) or No. 2 (for MR-J2S-B type).