Specifications
Servo Amplifier Specifications
64
MR-J2S-CL type
Voltage/frequency
(Note 1)
3-phase 200 to 230VAC 50/60Hz or
1-phase 230VAC 50/60Hz
(Note 2)
3-phase 200 to 230VAC 50/60Hz
(Note 2)
1-phase 100 to 120VAC
50/60Hz
(Note 2)
3-phase 200 to 230VAC: 170 to 253VAC
1-phase 230VAC: 207 to 253VAC
3-phase 170 to 253VAC
1-phase 85 to 127VAC
±5% max.
Sine-wave PWM control/current control system
Built-in
(Note 3)
Program language (programmed by the setup software) Program capacity: 120 steps
Set by the program language One-point feed length setting range: ±1 (µm) to ±999.999 (mm)
A servo motor speed, acceleration and deceleration time constants,
and S-pattern acceleration and deceleration time constants are set by the program language.
The S-pattern acceleration and deceleration time constants can be set by parameter No. 14 as well.
Signed absolute value command system, and signed incremental value command system
Depends on the setting of the program language
Inches upon contact input or RS-422 (RS-232C) communication based on speed commands set by a parameter.
Manual feed by manual pulse generator.
Command pulse ratio: Selectable ✕1, ✕10, or ✕100 by the parameter.
Returns to home position upon Z phase pulse count after passing through near-point dog.
Selectable direction for return to home position, settable home position shift and settable home position address.
Automatic retreat on dog back to home position and automatic stroke retreat function.
Returns to home position upon sensor pulse count after touching near-point dog.
Selectable direction for return to home position, settable home position shift and settable home position address.
Automatic retreat on dog back to home position and automatic stroke retreat function.
Returns to home position without dog. Set any position as the home position using manual operation or the like.
Settable home position address.
Returns to home position upon hitting end of stroke.
Selectable direction for return to home position. Settable home position address.
Uses position where the servo on signal (SON) becomes ON as home position. Settable home position address.
Returns to home position with respect to the rear end of a near-point dog.
Selectable direction for return to home position, settable home position address and settable home position shift.
Automatic retreat on dog back to home position and automatic stroke retreat function.
Returns to home position with respect to the front end of a near-point dog.
Selectable direction for return to home position, settable home position address and settable home position shift.
Automatic retreat on dog back to home position and automatic stroke retreat function.
Returns to home position with respect to the front end of a near-point dog by the first Z-phase pulse.
Selectable direction for return to home position, settable home position address and settable home position shift.
Automatic retreat on dog back to home position and automatic stroke retreat function.
Absolute position detection, backlash correction,
overtravel protection by the external limit switch, software stroke limit, override by external analog control
Self-cooling, open (IP00) Fan cooling, open (IP00) Self-cooling, open (IP00)
0 to 55°C (32 to 131°F) (non freezing), storage: –20 to 65°C (–4 to 149°F) (non freezing)
90% RH max. (non condensing), storage: 90% RH max. (non condensing)
Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist, or dust
5.9m/s
2
max.
Overcurrent shutdown, regeneration overvoltage shutdown, overload shutdown (electronic thermal), servo motor
overheat protection, encoder fault protection, regeneration fault protection, undervoltage/sudden power outage
protection, overspeed protection, excess error protection
Permissible voltage
fluctuation
Permissible frequency fluctuation
Power supply
Control system
Dynamic brake
Safety features
Operating specification
Program
Input positioning command
Input speed command
System
JOG
Manual pulse generator
Program operation mode
Manual
operation
mode
Structure
Other functions
Ambient humidity
Ambient temperature
Atmosphere
1000m (3280ft) or less above sea level
Elevation
Vibration
Mass (kg [lb])
Manual
home
position
return
mode
Environment
10CL 20CL 40CL 60CL 100CL 200CL 350CL 500CL 10CL1 20CL1 40CL1
Dog system
Dog system rear end
reference
Count system front end
reference
Dog cradle system
Count system
Data set system
Impact system
Ignore home (Servo-on
position as home position)
0.7
(1.5)
0.7
(1.5)
1.1
(2.4)
1.1
(2.4)
1.7
(3.7)
1.7
(3.7)
2.0
(4.4)
2.0
(4.4)
4.9
(10.8)
7.2
(15.9)
0.7
(1.5)
0.7
(1.5)
1.1
(2.4)
Notes:1.
2.
3.
Rated output and rated speed of the servo motor used in combination with the servo amplifier are as indicated when using the power supply voltage and frequency listed. The torque
drops when the power supply voltage is less than specified.
For torque characteristics when combined with a servo motor, refer to “servo motor torque characteristics” in this catalog.
For products without a dynamic brake (MR-J2S-MCL-ED or MR-J2S-MCL1-ED), special compliance is possible.
Servo amplifier model MR-J2S-
Command methodOperating mode
70CL
(-UM)
700CL
(-UM)