Specifications
Peripheral Equipment (MR-J2S-MA)
Connections with peripheral equipment
Peripheral equipment is connected to MR-J2S-A as described below.
Connectors, options, and other necessary equipment are available so that users can set up MR-J2S-A easily and begin using it right away.
RST
CN1A
CN1B
CN3
(Note 3)
TE2
Type 3 ground
or above
UVW
CN2
XY
L21
D
C
P
L11
Z
L1
L2
L3
Used to protect the power
supply line.
Circuit breaker
(NFB)
Power supply
3-phase 200-230VAC
or
1-phase 230VAC
(Note 1)
Used to turn off the servo
amplifier’s power when an
alarm has been triggered.
Magnetic contactor
(MC)
Power factor
improvement
reactor
(FR-BAL)
<With front cover open>
Charge lamp
Illuminates when the main circuit power supply is
ON. Do not plug/unplug power lines when this
lamp is ON.
Control signal (for operation panel)
Connected to the PLC’s I/O port or the
machine’s operation panel.
CN3 for RS-232C communication (option)
Connect the unit to user’s personal
computer to perform monitoring, batch
parameter entry and saving, graph display,
and test operation. Dedicated cable and
MR Configurator (setup software) are
available also.
(Note 2)
Optional regeneration unit (option)
Install this unit in situations involving fre-
quent regeneration and large load iner-
tia moments. Connect this unit referring
to “Standard Wiring Diagram”.
Notes: 1. If a 1-phase power supply (230VAC) is used, please connect it to terminals L1 and L2. Nothing should be connected to L3.
2. RS-232C and RS-422 are mutually-exclusive features. RS-422 communication is possible with parameter switching.
The RS-422 communication cable can be made by using the optional CN1 connector (MR-J2CN1).
3. The connections with the peripheral devices shown above apply for the MR-J2S-350A or smaller. Connect the MR-J2S-500A or larger and the MR-J2S-60A4 (400V type) or larger as
shown in the standard connection diagram.
HC- FS servo motor and encoder
(Above picture is HC-KFS23.)
Junction terminal block (option)
All signals can be recieved
easily at this terminal block
without a connection to
CN1A or CN1B.
FX
2N-10GM
FX
2N-20GM
FX
2N-1PG
FX
2N-10PG
QD75P
P1, 2, 4
AD75P
P1 to P3
QD75D
D1, 2, 4
A1SD75P
P1 to P3
Positioning controllers
The MR-J2S-A can be connected to a
Mitsubishi controller or any pulse train
output controller.
Battery compartment (option)
Display panel
Setting section
A battery (MR-BAT) is installed in the holder when
your servo system is an absolute system. Not re-
quired when your servo system is an incremental
system.
Displays monitoring data, parameters,
and alarms.
Parameter settings and monitoring
etc. are executed with push buttons.
Control signal
connector
Servo amplifier
MR-J2S- A
34