Specifications
Specifications and Characteristics
19
HC-RFS series servo motor specifications
Servo motor series HC-RFS series (Ultra-low inertia, medium capacity)
Servo motor model HC-RFS
Servo-amp model MR-J2S-
(Note 6)
Power facility capacity (Note 1) (kVA)
Rated output (kW)
Rated torque (N·m [oz·in])
Maximum torque (N·m [oz
·
in])
Rated speed (r/min)
Maximum speed (r/min)
Permissible instantaneous speed (r/min)
Power rate at continuous rated torque (kW/s)
Rated current (A)
Maximum current (A)
With no options
MR-RB30 (300W)
MR-RB50 (500W) (Note 5)
Standard
With electromagnetic brake
Recommended load/motor inertia moment ratio
Speed/position detector
Attachments
Structure
Ambient temperature
Ambient humidity
Atmosphere
Elevation/vibration (Note 4)
Mass
(kg [lb])
Standard
With electromagnetic brake
Regenerative
braking frequency
(times/min) (Note 2)
Moment of inertia
J (×10
-
4
kg·m
2
)
[J (oz
·
in
2
)]
Continuous
running duty
Specifications
Models
Servo motor
Environment
Notes:1.
2.
3.
4.
5.
6.
7.
The power facility capacity varies depending on the power supply’s impedance.
The regenerative brake frequency shows the permissible frequency for decelerating the motor without a load from rated speed to a stop. When a load is connected, however, the value
becomes the table value divided by (m+1) where m is the load inertia moment divided by the motor inertia moment. When the rated speed is exceeded, the regenerative brake frequen-
cy is inversely proportional to the square of (Operating speed/rated speed). When the operating speed varies with the frequency or when regeneration is constant (as with vertical
feeds), find the regeneration heat generated (W) while operating and do not exceed the permissible value.
Contact Mitsubishi if the load/motor of inertia moment ratio exceeds the value in the table.
The vibration direction is shown in the right-side diagram. The numeric value indicates the maximum value of the component (commonly the bracket in the opposite
direction of the motor shaft). Fretting of the bearing occurs easily when a motor stops, so please maintain vibration to approximately one-half of the allowable value.
Install a cooling fan (approx. 1.0m
3
/min, M92).
MR-J2S-MCP (1)-S084 is also compatible. The compatible motor is the same as the MR-J2S-MCP (1).
The amplifier software version compatible with the HC-RFS series 3.5kW/5.0kW is as follows.
A type:Version B0 or above B type:Version B0 or above
X
Y
103 (B) 153 (B) 203 (B) 353 (B) 503 (B)
200A/B/CP/CL 350A/B/CP/CL
500A/B/CP/CL
(Note 7)
1.7
1.0
3.18 (450.3)
7.95 (1125.7)
2.5
1.5
4.78 (676.8)
11.9 (1685.0)
3.5
2.0
6.37 (902.1)
15.9 (2251.4)
5.5
3.5
11.1 (1571.8)
27.9 (3950.6)
7.5
5.0
15.9 (2251.4)
39.7 (5621.5)
3000
4500
5175
67.4 120 176 150 211
6.1 8.8 14 23 28
18.4 23.4 37 58
174
401
669
70
125
288
479
1090 860 710
3270 2580 2130
5450 4300 3550
1.5 (8.2) 1.9 (10.4) 2.3 (12.6)
8.6 (47.0) 12.0 (65.6)
1.85 (10.1) 2.25 (12.3) 2.65 (14.5)
11.8 (64.5) 15.5 (84.7)
5 times the servo motor’s inertia moment max. (Note 3)
17-bit encoder (Resolution per encoder/servo motor rotation: 131072 p/rev)
Oil seal
Totally enclosed non ventilated (protection level: IP65)
0 to 40°C (32 to 104°F) (non freezing), storage: −15 to 70°C (5 to 158°F) (non freezing)
80% RH max. (non condensing), storage: 90% RH max. (non condensing)
Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist, or dust
1000m (3280ft) or less above sea level; X: 24.5 m/s
2
, Y: 24.5 m/s
2
3.9 (8.6) 5.0 (11.0) 6.2 (13.7) 12 (26.4) 17 (37.5)
6.0 (13.2) 7.0 (15.4) 8.3 (18.3) 15 (33.0) 21 (46.3)
HC-RFS series servo motor torque characteristics
1000 2000 3000 4000 4500
Speed (r/min)
3
0
6
9
1000 2000 3000 4000 4500
Speed (r/min)
5
10
15
1000 2000 3000 4000 4500
Speed (r/min)
6
12
18
1000 2000 3000 4000 4500
Speed (r/min)
10
20
30
1000 2000 3000 4000
Speed (r/min)
15
30
45
4500
0
0
0
0
Peak running range
Continuous running
range
Peak running range
Continuous running
range
Peak running range
Continuous running
range
Peak running range
Continuous running
range
Peak running range
Continuous running
range
1260
840
420
0
Torque (oz
•
in)
Torque (N
•
m)
HC-RFS103 (B) (Note 1)
4200
2800
1400
0
Torque (oz
•
in)
Torque (N
•
m)
HC-RFS353 (B) (Note 1)
2100
1400
700
0
Torque (oz
•
in)
Torque (N
•
m)
HC-RFS153 (B) (Note 1)
2520
1680
840
0
Torque (oz
•
in)
Torque (N
•
m)
HC-RFS203 (B) (Note 1)
6300
4200
2100
0
Torque (oz
•
in)
Torque (N
•
m)
HC-RFS503 (B) (Note 1)
Note:
1. : For 3-phase 200VAC.