Instruction manual

1 - 2
1. FUNCTIONS AND CONFIGURATION
1.2 Servo amplifier standard specifications
Servo amplifier
Item
MR-J2-03B5
Voltage 21.6 to 30VDC (instantaneous permissible voltage 34V)
HC-AQ0135D Continuous 0.8A, max. 2.4A
HC-AQ0235D Continuous 1.6A, max. 4.8A
Circuit
power
supply
(Note)
Power supply
capacity
HC-AQ0335D Continuous 2.4A, max. 7.2A
Control circuit power supply
(Note)
24VDC
10% 200mA (400mA when using the servo motor equipped with electromagnetic
brake)
System Sine-wave PWM control, current control system
Dynamic brake Built-in
Protective functions
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic
thermal relay), servo motor overheat protection, encoder fault protection, undervoltage,
instantaneous power failure protection, overspeed protection, excessive error protection
Speed frequency response 250Hz or more
Structure Open (IP00)
[ ]0 to 55 (non-freezing)
Operation
[
] 32 to 131 (non-freezing)
[ ] 20 to 65 (non-freezing)
Ambient
temperature
Storage
[
] 4 to 149 (non-freezing)
Operation
Ambient
humidity
Storage
90%RH or less (non-condensing)
Ambient
Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude Max. 1000m (3280ft) above sea level
[m/s
2
] 5.9 or less
Environment
Vibration
[ft/s
2
] 19.4 or less
[kg] 0.2
Weight
[lb] 0.44
Note: To comply with the low voltage directive, use a reinforced insulation stabilizing power supply.
1.3 Function list
The following table lists the functions of this servo. For details of the functions, refer to the reference field.
Function Description Reference
Slight vibration suppression
control
Suppresses vibration of
1 pulse produced at a servo motor stop. Section 6.5
Real-time auto tuning
Automatically adjusts the gain to optimum value if load applied to the servo
motor shaft varies.
Section 6.2
Section 6.3
Parameter No.9
Torque limit Servo motor torque can be limited to any value.
Parameter No.10
Parameter No.11
External forced stop signal
automatic ON
Forced stop (EM1) can be automatically switched on internally to invalidate it. Parameter No.23
Test operation mode
Servo motor can be run from the operation section of the servo amplifier
without the start signal entered.
Section 4.4
Servo configuration software
Using a personal computer, parameter setting, test operation, status display,
etc. can be performed.
Section 11.1.2