Instruction manual
11 - 18
11. OPTIONS AND AUXILIARY EQUIPMENT
(b) Cable clamp fitting (AERSBAN -SET)
Generally, the earth of the shielded cable may only be connected to the connector's SD terminal.
However, the effect can be increased by directly connecting the cable to an earth plate as shown
below.
Install the earth plate near the servo amplifier for the encoder cable. Peel part of the cable sheath
to expose the external conductor, and press that part against the earth plate with the cable clamp.
If the cable is thin, clamp several cables in a bunch.
The clamp comes as a set with the earth plate.
Strip the cable sheath of
t
he clamped area.
cutter
cable
Cable clamp
(A,B)
Cable
Earth plate
External conductor
Clamp section diagram
40(1.57)
Outline drawing
Earth plate Clamp section diagram
(Note)M4 screw
11(0.43)
3 (0.12)
6 (0.24)
C
A
6
22(0.87)
17.5(0.69)
35(1.38)
35 (1.38)
L or less
10(0.39)
30
(
1.18
)
7 (0.28)
24
0
0.2
Note: Screw hole for grounding. Connect it to the earth plate of the control box.
(0.24)
24
0.3
0
(
0.940
)
(0.940)
[Unit: mm]
([Unit: in])
B
0.3(0.01)
2- 5(0.20) hole
installation hole
Type A B C Accessory fittings Clamp fitting L
AERSBAN-DSET
100
(3.94)
86
(3.39)
30
(1.18)
clamp A: 2pcs. A
70
(2.76)
AERSBAN-ESET
70
(2.76)
56
(2.20)
clamp B: 1pc. B
45
(1.77)