Instruction manual

5.
PARAMETERS
-
jymbo
INP
-
PG1
PST
sc1
-
sc2
-
Name and Function
In-position range:
~ ~ ~~~
Used to set the droop pulse range In which the imposition
(INP
signal will be output.
Position loop gain
1:
Used to set the gain
of
position loop
1.
Increase the gain
to
improve trackability in response
to
the positior
command.
Position command
accelerationldeceleration
time constant
(smoothing):
Used to set the time constant
of
a low pass filter in response to the
position command.
Example: When a command is given from a synchronizing detector,
synchronous operation can be started
smoothly
if
started during line
operation.
Servo amplifier
-_
,.
I.
Without time
constant settin?
/
..'
With time
Servo motor
/
constant setting
speed
ON
j
t
Start
9
Internal speed command
1:
Used to set speed
1
of
internal speed commands
Internal speed limit
1:
Used to set speed
1
of
internal speed limits.
Internal speed command
2:
Used to set speed
2
of
internal speed commands.
Internal speed limit
2:
Used to set speed
2
of
internal speed limits.
5-
6
-
Initial
Value
100
-
145
3
100
500
7
Unit
pulse
-
-
redls
-
ms
rimir
-
r/mir
-
Setting
Range
0
to
-
-
10000
4
to
1000
-
0
to
20000
-
0
to
instan-
taneou!
perm-
ssible
-
speed
0
to
instan-
taneou:
permi-
ssible
speed
-
S
T
-
S
T
-