PARAMETERS
5.
PARAMETERS
Never adjust or change the parameter values extremely as it will make operation
instable.
~~~ ~ ~
5.1
Parameter List
5.1.1
Parameter write inhibit
I
POINT
1
After setting the parameter
No.
19
value, switch power
off,
then on to make
that setting valid.
r
In the
MR-J2-03A5
servo amphfier, its parameters are classdied
into
the basic parameters
(No.
0
to
19)
and expansion parameters
(No.
20
to
49)
according
to
their safety aspects and frequencies
of
use. In the
factov setting conchtion, the customer can change the basic parameter values but cannot change the
expansion parameter values. When fine adjustment, e.g. gain adjustment,
is
required, change the
parameter
No.
19
setting
to
make the expansion parameters write-enabled.
Parameter No.
19
Setting
Operation
Basic Parameters Expansion Parameters
No.
0
to
No.
19
No.
20
to
No.
49
0000
Reference
~
c~n~tlal
value)
Write
Reference
Write
0OO.A
I
OOOB
Reference
0
0
Write
0
oooc
Reference
0
0
Write
0
0
5-
1