Instruction manual
3.
SIGNALS AND
WIRING
(3)
Forced stop
A
CAUTION
To stop operation and switch power
off
immediately, provide a forced stop circuit.
Make up a circuit whch shuts
off
main circuit power as soon
as
EMG-SG are opened
at
a forced stop.
To
ensure safety, always
install
a forced stop switch across
EMG-SG.
By
&sconnecting EMG-SG, the
dynamic brake
is
operated to bring the servo motor to a sudden stop. At
ths
time, the &splay shows the
servo forced stop warning (A.
E6).
During ordmary operation, do not use the forced stop signal
to
alternate stop and
run.
If the start signal is on or
a
pulse train
is
input during a forced
stop,
the servo motor
wdl
rotate as soon
as the warning is reset. During a forced stop, always shut
off
the run command.
Servo amplifier
(4)
CNP1
connector wiring
The servo amphfier is packed with the following parts for wiring the CNP1.
For connection of the terminals and cables, use the crimping tool 57026-5000 (for UL1007) or 57027-
5000
(for UL1015).
Part
molex
Maker
Model
Connector
5556
Terminal
5557-08R
3-