Instruction manual

A
CAUTION
Provide an external emergency stop circuit
to
ensure that operation can be stopped and power switched
off
immediately.
Any person who is involved in disassembly and repair should be fully competent to do the work.
Before resetting an alarm, make sure that the run signal is
off
to prevent an accident. A sudden restart is
made
if
an alarm is reset with the run signal
on.
Do
not modify the equipment.
Use a noise filter, etc. to minimize the influence of electromagnetic interference, which may be caused by
electronic equipment used near the servo amplifier.
Use the servo amplifier with the specified servo motor.
The electromagnetic brake on the servo motor is designed to hold the motor shaft and should not be used
for ordinary braking.
For such reasons as sewice life and mechanical structure (e.g. where a ballscrew and the servo motor are
coupled via a timing belt), the electromagnetic brake may not hold the motor shaft.
To
ensure safety, install
a stopper on the machine side.
(5)
Corrective actions
L
!
A
CAUTION
When it
is
assumed that a hazardous condition may take place at the occur due to a power failure or a
product fault, use a servo motor with electromagnetic brake or an external brake mechanism for the
purpose of prevention.
When any alarm has occurred, eliminate its cause, ensure safety, and deactivate the alarm before
restarting operation.
When power is restored after an instantaneous power failure, keep away from the machine because the
machine may be restarted suddenly (design the machine
so
that it is secured against hazard
if
restarted).
(6)
Maintenance, inspection and parts replacement
L
.
A
CAUTION
<
With age, the electrolytic capacitor will deteriorate.
To
prevent a secondary accident due to a fault, it is
recommended to replace the electrolytic capacitor every
10
years when used in general environment.
A-
5