Instruction manual
3.
SIGNALS AND WIRING
3.
SIGNALS AND WIRING
Any person who is involved in wiring should be fully competent to do the work.
Before starting wiring, make sure that the voltage is safe in the tester more than
10
Ground the servo amplifier and the servo motor securely.
Do
not attempt to wire the servo amplifier and servo motor until they have been
The cables should not be damaged, stressed excessively, loaded heavily, or
minutes after power-off. Otherwise, you may get an electric shock.
AWARNING
installed. Otherwise, you may get an electric shock.
pinched. Otherwise, you may get an electric shock.
ACAUTION
Wire the equipment correctly and securely. Otherwise, the servo motor may
Connect cables to correct terminals to prevent a
burst,
fault, etc.
Ensure that polanty
(+,
-)
is correct. Otherwise, a
burst,
damage, etc. may occur.
The surge absorbing diode installed to the
DC
relay designed for control output
misoperate, resulting in injury.
should be fitted in the specified direction. Otherwise, the signal is not output due to
a fault, disabling the forced stop and other protective circuits.
[NO
ap
(24VDC)
Control
output
signal
Use
a
noise filter, etc. to minimize the influence
of
electromagnetic interference,
Do
not install a power capacitor, surge suppressor or radio noise filter with the power
Do
not modify the equipment.
which may be given
to
electronic equipment used near the servo amplifier.
line
of
the servo motor.
POINT
I
CNlA
and
CNlB
have the same shape. Wrong connection
of
the connectors
wdl
lead
to
a failure. Connect them correctly.
3-