Instruction manual

6.
DISPLAY AND OPERATION
6.5
Parameter
mode
The servo amphfier
is
factory-set
in
the position control mode. Change the parameter settings when:
*
The control mode
is
changed;
*
The number of pulses per servo
motor
revolution
is
changed;
or
*
The machme mounted with the servo motor hunts
or
operational performance
is
further improved.
Some parameters are made valid by changing the setting and then switchmg power
off
once and switchmg
it on again. (Refer
to
Section
5.1.2.)
(1
)
Operation
example
(a) 4-d1gt parameter
The following example shows the operation procedure performed after power-on
to
change the
control mode (parameter
No.
0)
to
the speed control mode.
I
I
a
,
Press MODE
0
three times
Press UP once.
...
During flickering, the set value can be changed.
Use
UP
Or
DOWN'
00
(0002:
Speed control mode)
0
Press
SET
to
enter.
01
0
To
sMt to the next parameter, press the
UP
DOWN button.
When changing the parameter
No.
0
setting, change
its
set value, then switch power
off
once and switch
it
on again to make the new value valid.