Specifications
4 - 42
4.3.9 Current value changing
Changing current value of stop position
(1) Change the [Current feed data] to a desired value using the current value
changing instruction at a stop or during the continuous positioning control.
(The current value changing cannot be executed during the continuous path
control.)
(2) Set a new value in the [Positioning address] column.
(3) When this instruction is executed, the current feed value is changed, and the
machine feed value is kept.
Item Need of setting
Operation pattern
Control system "Current value changing"
Axis to be
interpolated
Acceleration time No.
Deceleration time No.
Positioning address
Arc address
Command speed
Dwell time
M code
The current feed value of
the stop position can be changed.
0
0
100 200
100
200
(mm)
50
REMARK
The current feed value can also be changed by storing a new value to the buffer
memory (1506, 1507/1606, 1607/1706, 1707/1806, 1807) using the positioning
data No.9003 and the DTO instruction.