Specifications

4 - 41
4.3.8 NOP instruction
Instruction to execute nothing
(1) The NOP instruction is used for the control system that executes nothing.
When the NOP instruction is selected as the control system, all settings
(positioning address, command speed, etc.) other than the control system are
invalid.
(2) The positioning data No. to which the NOP instruction is set is skipped, without
any processing, to the operation for the next positioning data No.
However, when the NOP instruction is set to the positioning data No.600, an error
will occur.
REMARK
The NOP instruction is used for reserving the data if there is a possibility of
executing speed switching or temporary stop (automatic deceleration) somewhere
in the positioning control.
The data can be changed simply by replacing the identifier.