Specifications
4 - 32
Positioning address
(a) Absolute (ABS) system, current value changing
• The setting value (end point address) for the ABS system and current value
changing is set with an absolute address (address from OP).
-1000 3000
Stop position (Positioning start address)
Movement amount:2000
1000
Movement amount:2000
(b) Incremental (INC) system, fixed-feed 1, fixed-feed 2, fixed-feed 3, fixed-feed 4
• The movement amount (with a sign) for the INC system is set.
• Movement direction is specified with a sign.
When movement amount is positive: Moves in the positive direction (address
increment direction)
When movement amount is negative: Moves in the negative direction (address
decrement direction)
Move in negative direction Move in positive direction
-30000
30000
Stop position (Positioning start position)
(Movement amount) (Movement amount)
(c) Speed-position switching control
• Set the amount of movement after the switching from speed control to position
control.
(d) Position-speed switching control
• Set the amount of movement during position control (before the switching to
speed control).
Arc address
The arc address is data required only when carrying out the circular interpolation
control.
(1) When carrying out circular interpolation with a sub point designated, set the sub
point (passing point) address.
(2) When carrying out circular interpolation with a center point designated, set the
center point address of the arc.
End point address
Sub point
Start point address
End point address
Center point address
Start point address
<Circular interpolation with sub point designated> <Circular interpolation with center point designated>