Specifications

4 - 30
Operation pattern
The operation pattern designates whether positioning of a certain data No. is to be
completed with just that data, or whether the positioning is to be carried out with the
next data No. in succession.
Operation pattern
Positioning
complete
................................................................................................Complete
Continuous positioning with one start signal ............... Continued
Positioning
continued
Continuous path positioning with speed change......... Path
(1) Positioning complete ...Set to execute positioning to the designated address, and
then complete positioning after the dwell time has passed.
Start complete
(X10)
Start (Y10)
BUSY(X0C)
Dwell time
Complete
Speed
Time
···Turn ON/OFF
automatically in the QD75
···Turn ON/OFF by
the sequence program
Figure 4.11 Pattern [Complete]
(2) Continuous positioning control .... Positioning is carried out successively in order of
data Nos. with one start signal. (the BUSY signal
remains ON during positioning continued.)
Start complete
(X10)
Start (Y10)
BUSY(X0C)
V
3
V
2
V
1
Continuous Continuous
Complete
V
1
and V
2
indicate that the positioning direction is reversed.
Speed
Dwell
time
Time
Dwell
time
Dwell
time
Figure 4.12 Pattern [Continued]