Specifications
4 - 27
OP shift amount from zero
The OP shift function is used to compensate the OP position obtained by the OPR.
With the OP shift function, the OP position can be shifted to a point between zero
points or point far from zero point detected.
Zero signal
Near-point dog
Start point
Shift point
Shift point
OPR direction
When OP shift amount is
positive
When OP shift amount
is negative
Shift after deviation
counter clear is canceled
Figure 4.10 OP shift