Specifications
4 - 24
OP address
After the completion of OPR, the current position is set as the specified address. This
newly specified address can be the reference value of absolute positioning.
This OP address is stored in "current feed value" and "machine feed value" when the
OPR is completed.
OPR speed
Set the speed of OPR.
Set the OPR speed within the following range.
Speed limit value
≥
OPR speed
≥
Creep speed
≥
Bias speed at start
Creep speed
Set the creep speed (the low speed just before a stop, after decelerating from the OPR
speed) that comes after near-point dog turns ON.
The creep speed is set within the following range.
OPR speed
≥
Creep speed
≥
Bias speed at start