(2) In the condition that the positioning pattern is set to "continuous positioning"
and the set time of the positioning complete signal is shorter than the next
positioning operation time, the positioning complete signal turns ON when the
next data No. starts operation after the previous dwell time has passed.
It turns OFF when the set time has elapsed.
Dwell
Dwell Dwell
Setting time Setting time Setting time
Continuous Continuous Complete
Positioning complete signal
(3) In the condition that the positioning pattern is set to "continuous positioning"
and the set time of the positioning complete signal is longer than the next
positioning operation time, the positioning complete signal turns ON when the
next data No. starts operation after the previous dwell time has passed.
However, if the next data No. continuously starts operation before the set time
has elapsed, the elapsed time is ignored and the set time starts elapsing from
the beginning.
It turns OFF when the set time has elapsed.
Dwell Dwell
ignored and restarts counting.
Setting time
Setting time
Continuous Continuous Complete
Positioning complete signal
The time elapsed up to here is
(4) When the positioning pattern is set to "continuous path", the positioning
complete signal turns ON at speed alteration and moves onto the positioning
of the next data No.
Dwell Dwell
Setting time Setting time
Complete Path
Positioning complete signal
Setting time Setting time
Path
Complete
Start command
(Note) When the setting time of the positioning complete signal is longer than the
next positioning operation time, the operation of the path is as explained in
3).