Specifications

4 - 13
Torque limit setting value
The torque limit function limits the torque generated by the servomotor within the set
range.
If the torque required for control exceeds the torque limit value, the control is
performed with the set torque limit value.
Usage
(1) Limitation for pulse train output type
(a) Wiring for a D/A conversion module and wiring between a D/A conversion
module and drive unit must be made.
(b) A drive unit that can issue the torque limit command with the analog voltage
is required.
(c) The torque limit setting value is set in the buffer memory area "torque limi
t
stored value (826, 926, 1026, and 1126)". Transmit that "torque limit stored
value" to the D/A conversion module with the sequence program.
M code ON signal output timing
An M code is a number between 0 and 65535 that can be assigned to each positioning
control.
(1) The sequence program can be coded to read an M code from the buffer memory
address specified by "Valid M code (808, 908, 1008, and 1108)" whenever the M
code ON signal [X4, X5, X6, X7] turns ON so that a command for the sub work
(e.g. clamping, drilling, tool change) associated with the M code can be issued.
(2) Choose either the WITH mode or the AFTER mode as the M code ON signal
output timing.
WITH mode ...... An M code is output and the M code ON signal is turned ON when
positioning operation starts.
*: m1 and m2 indicate set M codes.
m1 m2
01 (continuous) 00 (end)
Positioning start
BUSY
M code
Positioning
Operation pattern
M code ON signal
(X4,X5,X6,X7)
**
M code OFF request
(1504,1604,1704,1804)