Specifications

3 - 9
(2) Common functions
The outline of the functions executed as necessary is described below.
(Refer to QD75 User
'
s Manual for details on each function.)
Common functions Details
Parameter initialization function
This function returns the "parameters" stored in the QD75 buffer
memory and flash ROM to the default values.
The following two methods can be used.
1) Method using a sequence program
2) Method using SW D5C-QD75P
Execution data backup function
This function stores the "setting data", currently being executed,
into the flash ROM.
The following two methods can be used.
1) Method using a sequence program
2) Method using SW
D5C-QD75P
I/O signal logic switching function
This function switches I/O signal logic according to externally
connected devices.
This function enables the use of the system that does not use
normally close signals, such as the drive unit READY or
upper/lower limit signal, by setting parameters to positive logic.