Specifications

3 - 6
Main functions Details
JOG operation Outputs a pulse while the JOG start signal is ON.
Inching operation
Outputs pulses corresponding to minute movement amount by manual
operation.
(Performs fine adjustment with the JOG start signal.)
Manual control
Manual pulse
generator operation
Outputs pulses sent from the manual pulse generator to servo amplifier.
(Carries out fine adjustment, etc., at the pulse level.)
Operation pattern Details
Independent positioning
control
(Positioning complete)
When "independent positioning control" is set for the operation pattern of the
started positioning data, only the designated positioning data will be executed,
and then the positioning will end.
Continuous positioning
control
When "continuous positioning control" is set for the operation pattern of the
started positioning data, after the designated positioning data is executed, the
program will stop once, and then the next following positioning data will be
executed.
Continuous path control
When "continuous path control" is set for the operation pattern of the started
positioning data, the designated positioning data will be executed, and then
without decelerating, the next following positioning data will be executed.