Specifications

6 - 41
Demonstration machine operation
1) Turn X0 ON to carry out OPR.
2) Set the digital switch to 61.
Setting of positioning
data No.
0
1
600000
X3F to X30 X2F to X20
Turn X3 ON for the forward run.
The axis-1 current value of the SW
D5C-QD75P operation monitor screen
remains "0" and is not incremented.
Confirm that the speed is displayed.
Turn X1 ON during the operation to stop the operation.
3) Set the digital switch to 62.
Setting of positioning
data No.
0
2
600000
X3F to X30 X2F to X20
Turn X3 ON for the reverse run.
The axis-1 current value of the SW
D5C-QD75P operation monitor screen
remains "0" and is not decremented.
Confirm that the speed is displayed.
Turn X1 ON during the operation to stop the operation.
REFERENCE
If an error occurs, move to the center by the JOG operation and turn X0B (Error reset) ON.
Repeat