Specifications
6 - 38
Demonstration machine operation
1) Turn X2 ON and return to the standby point of 25mm.
2) Set the digital switch and write the speed V to the buffer memory by X7.
Turn
X8 OFF.
Turn
X7 ON.
4
0
Setting of
positioning data No.
014
0
Set between 0044
to 9999
44
X3F to X30
mm/min
Speed V
(2414, 2417)
X2F to X20
3) Set the digital switch and write the address P to the buffer memory by X8 and X7.
Setting of positioning
data No.
0140
Set between 0001
to 0100.
0440
X3F to X30
mm
Movement
amount P
(2416, 2417)
Turn
X8 ON.
Turn
X7 ON.
X2F to X20
For the movement amount, do not set the bigger
value than 100mm.
The upper limit of the stroke limit might be
exceeded.
4) Turn X3 ON.
Address 50 mm
of the data No.41.
Movement amount
of the data No.42.
=
End point+
Repeat